The use of a reconstructed three-dimensional solid model from CT to aid the surgical management of a total knee arthroplasty: a case study

被引:69
作者
Minns, RJ
Bibb, R
Banks, R
Sutton, RA
机构
[1] Univ Hosp N Durham, Dept Med Phys, Durham, England
[2] Univ Wales Inst, PDR, Cardiff, S Glam, Wales
[3] Hexham Gen Hosp, Dept Orthopaed Surg, Hexham, England
关键词
computerised tomography; knee prosthesis; bone modelling; three-dimensional reconstruction;
D O I
10.1016/S1350-4533(03)00050-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The use of a rapid prototyping method was utilised to produce a pre-operative solid model of the proximal tibia in a patient with a massive defect of the medial tibial plateau. The solid model was reconstructed from aligned sequential CT images of the knee. This was then used to determine the level of bone resection of the proximal tibia for the optimum placement of the tibial component of a total knee replacement. This technique gives the surgeon both the three-dimensional anatomical information needed to ascertain whether there is adequate bony support after cutting for the prosthesis, as well as a solid model on which to carry out the proposed surgery, before undertaking the procedure on the patient. (C) 2003 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:523 / 526
页数:4
相关论文
共 11 条
[1]
COMPUTED-TOMOGRAPHY IN THE ASSESSMENT AND PLANNING OF COMPLICATED TOTAL HIP-REPLACEMENT [J].
BARMEIR, E ;
DUBOWITZ, B ;
ROFFMAN, M .
ACTA ORTHOPAEDICA SCANDINAVICA, 1982, 53 (04) :597-604
[2]
BAUTSCH TL, 1994, CLIN ORTHOP RELAT R, V305, P138
[3]
Custom total hip arthroplasty [J].
Bert, JM .
JOURNAL OF ARTHROPLASTY, 1996, 11 (08) :905-915
[4]
McCarthy JC, 1997, CLIN ORTHOP RELAT R, P162
[5]
Migaud H, 1997, REV CHIR ORTHOP, V83, P156
[6]
CT-generated 3-dimensional models for complex acetabular reconstruction [J].
Munjal, S ;
Leopold, SS ;
Kornreich, D ;
Shott, S ;
Finn, HA .
JOURNAL OF ARTHROPLASTY, 2000, 15 (05) :644-653
[7]
Three-dimensional computer analysis of complex acetabular insufficiency [J].
Roach, JW ;
Hobatho, MC ;
Baker, KJ ;
Ashman, RB .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1997, 17 (02) :158-164
[8]
Uncemented press-fit total hip arthroplasty using the identifit custom-molding technique - A prospective minimum 2-year follow-up study [J].
Robinson, RP ;
Clark, JE .
JOURNAL OF ARTHROPLASTY, 1996, 11 (03) :247-254
[9]
Early results of the Minns meniscal bearing total knee prosthesis [J].
Shaw, NJ ;
Minns, RJ ;
Epstein, HP ;
Sutton, RA .
KNEE, 1997, 4 (04) :185-191
[10]
SWAELENS B, 1996, STEREOLITHOGRAPHY OT, P339