Factors contributing to peak broadening and mass accuracy in the characterization of intact spores using matrix-assisted laser desorption/ionization coupled with time-of-flight mass spectrometry

被引:25
作者
Ramirez, J [1 ]
Fenselau, C [1 ]
机构
[1] Univ Maryland, Dept Chem & Biochem, College Pk, MD 20742 USA
来源
JOURNAL OF MASS SPECTROMETRY | 2001年 / 36卷 / 08期
关键词
spores; MALDI-TOF; peak broadening; mass assignment; biomarker;
D O I
10.1002/jms.196
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Factors contributing to peak broadening, accuracy and precision in mass assignment in the matrix-assisted laser desorption/ionization characterization of a lipopeptide desorbed from intact Bacillus spores were investigated. These spores were studied as an example of a thick, topologically irregular sample, which present a more difficult target than a pure peptide or protein. The type of matrix, matrix:sample ratio, laser fluence, and localized repetitive laser irradiation were all found to affect the full-width at half maximum of the biomarker. Both in-source and post-source phenomena were shown to contribute. Sample thickness had less effect. Precision and accuracy of mass assignment were also affected by matrix:sample ratio and laser fluence. In general, this sample was responsive to the same experimental variables as pure peptides, and the use of an internal standard produced significant improvements in precision and accuracy. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:929 / 936
页数:8
相关论文
共 49 条
[1]  
[Anonymous], 1997, TIME FLIGHT MASS SPE
[2]   Monitoring the growth of a bacteria culture by MALDI-MS of whole cells [J].
Arnold, RJ ;
Karty, JA ;
Ellington, AD ;
Reilly, JP .
ANALYTICAL CHEMISTRY, 1999, 71 (10) :1990-1996
[3]  
Arnold RJ, 1998, RAPID COMMUN MASS SP, V12, P630, DOI 10.1002/(SICI)1097-0231(19980529)12:10<630::AID-RCM206>3.3.CO
[4]  
2-S
[5]  
Burton RD, 1997, RAPID COMMUN MASS SP, V11, P443, DOI 10.1002/(SICI)1097-0231(199703)11:5<443::AID-RCM897>3.0.CO
[6]  
2-3
[7]   Improved calibration of time-of-flight mass spectra by simplex optimization of electrostatic ion calculations [J].
Christian, NP ;
Arnold, RJ ;
Reilly, JP .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3327-3337
[8]   The rapid identification of intact microorganisms using mass spectrometry [J].
Claydon, MA ;
Davey, SN ;
EdwardsJones, V ;
Gordon, DB .
NATURE BIOTECHNOLOGY, 1996, 14 (11) :1584-1586
[9]  
Conway GC, 2001, J MOL MICROB BIOTECH, V3, P103
[10]   Microorganism identification by mass spectrometry and protein database searches [J].
Demirev, PA ;
Ho, YP ;
Ryzhov, V ;
Fenselau, C .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2732-2738