Sub-micron particle manipulation in an ultrasonic standing wave: Applications in detection of clinically important biomolecules

被引:21
作者
Sobanski, MA
Tucker, CR
Thomas, NE
Coakley, WT
机构
[1] Cardiff Univ, Sch Biosci, Cardiff CF10 3TL, S Glam, Wales
[2] Cardiff Univ, Dept Phys & Astron, Cardiff CF24 3YB, S Glam, Wales
基金
英国生物技术与生命科学研究理事会;
关键词
antigen detection; radial sound field; latex agglutination; ultrasound; ultrasonic standing wave;
D O I
10.1023/A:1011175404581
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Separation of particles from the suspending phase is of interest, among others, to clinical analysts. A system that enables manipulation of sub-micron sized particles in suspensions of analytical scale volume (10-50 mul) using a non-cavitating ultrasonic standing wave is described. Particle suspensions, contained in glass capillary tubes of 1-2 mm internal dimension, are treated on the axis of a tubular transducer generating a radial standing wave field at 4.5 MHz. Microparticles (of average diameter range 0.3-10 mum) suspended in buffer are concentrated within seconds at preferred regions separated by submillimetre distances. Concentration of suspended latex particles was inhibited in solutions containing protein at levels similar to those occurring in clinical specimens when the suspensions were sonicated in capillaries of circular cross-section. This effect was associated with acoustic streaming of the suspending fluid. Silica microparticles (more dense and less compressible than latex) could be concentrated in the presence of streaming. Latex particles concentrated readily in square cross-section capillaries where no streaming was observed. With sub-micron particles, the geometry of the sample chamber, the suspending phase composition and the size, density and compressibility of the microparticles all influence particle manipulation. The radial standing wave system has been used to enhance agglutination of antibody-coated latex microparticles in the presence of antigen allowing rapid and highly sensitive detection of clinically important biomolecules. The sensitivity of conventional diagnostic tests for microbial antigen has been improved by application of ultrasound and clinical utility has been demonstrated, in particular, for detection of meningitis-causing bacteria.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 25 条
[1]  
[Anonymous], 1984, GEIGY SCI TABLES
[2]   Preliminary clinical evaluation of meningococcal disease and bacterial meningitis by ultrasonic enhancement [J].
Barnes, RA ;
Jenkins, P ;
Coakley, WT .
ARCHIVES OF DISEASE IN CHILDHOOD, 1998, 78 (01) :58-60
[3]  
CHEN HQ, 1991, BIORHEOLOGY, V28, P177
[4]  
Coakley W. Terence, 1994, Bioseparation, V4, P73
[5]  
Coakley WT, 1997, TRENDS BIOTECHNOL, V15, P506, DOI 10.1016/S0167-7799(97)01122-0
[6]   Diagnostic particle agglutination using ultrasound: a new technology to rejuvenate old microbiological methods [J].
Ellis, RW ;
Sobanski, MA .
JOURNAL OF MEDICAL MICROBIOLOGY, 2000, 49 (10) :853-859
[7]   Ultrasound-enhanced latex immunoagglutination and PCR as complementary methods for non-culture-based confirmation of meningococcal disease [J].
Gray, SJ ;
Sobanski, MA ;
Kaczmarski, EB ;
Guiver, M ;
Marsh, WJ ;
Borrow, R ;
Barnes, RA ;
Coakley, WT .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (06) :1797-1801
[8]   RAPID AGGLUTINATION TESTING IN AN ULTRASONIC STANDING-WAVE [J].
GRUNDY, MA ;
BOLEK, WE ;
COAKLEY, WT ;
BENES, E .
JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 165 (01) :47-57
[9]   INCREASED SENSITIVITY OF DIAGNOSTIC LATEX AGGLUTINATION TESTS IN AN ULTRASONIC STANDING-WAVE FIELD [J].
GRUNDY, MA ;
MOORE, K ;
COAKLEY, WT .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 176 (02) :169-177
[10]  
GUALANO MP, 1995, BRIT J BIOMED SCI, V52, P178