Physical evaluation of 511 keV coincidence imaging with a gamma camera

被引:5
作者
Vandenberghe, S [1 ]
D'Asseler, Y
Koole, M
Van de Walle, R
Lemahieu, I
Dierckx, RA
机构
[1] State Univ Ghent, ELIS, MEDISIP, B-9000 Ghent, Belgium
[2] Univ Hosp, Div Nucl Med, Ghent, Belgium
关键词
D O I
10.1109/23.910838
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work presents an evaluation of a gamma camera operating in coincidence mode. The major limitations of these cameras compared to full-ring PET are the limited count rate and sensitivity. We evaluate the progress in count rate performance which was made by upgrading the system with digital electronics. At the moment most gamma cameras use septa to reduce the number of incident coincidences by limiting the axial acceptance angle. Higher count rates can be achieved by removing the sept, which results in a fully 3D acquisition. The improvement in Noise Equivalent Count rate is measured for two different uniform phantoms. Another limitation is the non-uniform sensitivity due to the varying acceptance angle, which decreases linearly from the center towards the edges in a 180 degrees opposed dual-headed configuration. Sensitivity and uniformity can be improved by going from a dual-headed to a triple-headed configuration. As triple-headed coincidence imaging is not yet available, we calculated the theoretical sensitivity profiles from geometrical considerations.
引用
收藏
页码:98 / 105
页数:8
相关论文
共 18 条
[1]   Optimization of noise-equivalent count rates in 3D PET [J].
Badawi, RD ;
Marsden, PK ;
Cronin, BF ;
Sutcliffe, JL ;
Maisey, MN .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (09) :1755-1776
[2]   Comparison of FDG PET and positron coincidence detection imaging using a dual-head gamma camera with 5/8-inch NaI(Tl) crystals in patients with suspected body malignancies [J].
Boren, EL ;
Delbeke, D ;
Patton, JA ;
Sandler, MP .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (04) :379-387
[3]  
DASSELER Y, 2000, P SPIE MED IM
[4]   AN ITERATIVE IMAGE SPACE RECONSTRUCTION ALGORITHM SUITABLE FOR VOLUME ECT [J].
DAUBEWITHERSPOON, ME ;
MUEHLLEHNER, G .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (02) :61-66
[5]   Exact and approximate rebinning algorithms for 3-D PET data [J].
Defrise, M ;
Kinahan, PE ;
Townsend, DW ;
Michel, C ;
Sibomana, M ;
Newport, DF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :145-158
[6]   A fast rebinning algorithm for 3D positron emission tomography using John's equation [J].
Defrise, M ;
Liu, XA .
INVERSE PROBLEMS, 1999, 15 (04) :1047-1065
[7]  
Delbeke D, 1999, J NUCL MED, V40, P110
[8]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .4. EFFECT OF ACCIDENTAL COINCIDENCES [J].
HOFFMAN, EJ ;
HUANG, SC ;
PHELPS, ME ;
KUHL, DE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (03) :391-400
[9]   PET in oncology: Will it replace the other modalities? [J].
Hoh, CK ;
Schiepers, C ;
Seltzer, MA ;
Gambhir, SS ;
Silverman, DHS ;
Czernin, J ;
Maddahi, J ;
Phelps, ME .
SEMINARS IN NUCLEAR MEDICINE, 1997, 27 (02) :94-106
[10]  
LEVKOVITZ R, 1999, 1999 INT M FULL 3D I, P216