Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study

被引:85
作者
van Hamersvelt, Robbert W. [1 ]
Schilham, Arnold M. R. [1 ]
Engelke, Klaus [2 ]
den Harder, Annemarie M. [1 ]
de Keizer, Bart [3 ]
Verhaar, Harald J. [4 ]
Leiner, Tim [1 ]
de Jong, Pim A. [1 ]
Willemink, Martin J. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, POB 85500, NL-3508 GA Utrecht, Netherlands
[2] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
[3] Univ Med Ctr Utrecht, Dept Nucl Med, Utrecht, Netherlands
[4] Univ Med Ctr Utrecht, Dept Geriatr Med, Utrecht, Netherlands
关键词
Dual-energy CT; Dual-layer spectral detectorCT; Dual energy X-Ray absorptiometry; Bone mineral density; Material decomposition; QUANTITATIVE COMPUTED-TOMOGRAPHY; ISCD OFFICIAL POSITIONS; ENERGY CT; TRABECULAR BONE; CLINICAL-USE; OSTEOPOROSIS; ATTENUATION; MANAGEMENT; ADULTS; DXA;
D O I
10.1007/s00330-017-4801-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
To investigate the accuracy of bone mineral density (BMD) quantification using dual-layer spectral detector CT (SDCT) at various scan protocols. Two validated anthropomorphic phantoms containing inserts of 50-200 mg/cm(3) calcium hydroxyapatite (HA) were scanned using a 64-slice SDCT scanner at various acquisition protocols (120 and 140 kVp, and 50, 100 and 200 mAs). Regions of interest (ROIs) were placed in each insert and mean attenuation profiles at monochromatic energy levels (90-200 keV) were constructed. These profiles were fitted to attenuation profiles of pure HA and water to calculate HA concentrations. For comparison, one phantom was scanned using dual energy X-ray absorptiometry (DXA). At both 120 and 140 kVp, excellent correlations (R = 0.97, P < 0.001) were found between true and measured HA concentrations. Mean error for all measurements at 120 kVp was -5.6 +/- 5.7 mg/cm(3) (-3.6 +/- 3.2%) and at 140 kVp -2.4 +/- 3.7 mg/cm(3) (-0.8 +/- 2.8%). Mean measurement errors were smaller than 6% for all acquisition protocols. Strong linear correlations (R-2 ae<yen> 0.970, P < 0.001) with DXA were found. SDCT allows for accurate BMD quantification and potentially opens up the possibility for osteoporosis evaluation and opportunistic screening in patients undergoing SDCT for other clinical indications. However, patient studies are needed to extend and translate our findings. aEuro cent Dual-layer spectral detector CT allows for accurate bone mineral density quantification. aEuro cent BMD measurements on SDCT are strongly linearly correlated to DXA. aEuro cent SDCT, acquired for several indications, may allow for evaluation of osteoporosis. aEuro cent This potentially opens up the possibility for opportunistic osteoporosis screening.
引用
收藏
页码:4351 / 4359
页数:9
相关论文
共 30 条
[1]
ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]
Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation [J].
Bamberg, Fabian ;
Dierks, Alexander ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Becker, Christoph R. ;
Johnson, Thorsten R. C. .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1424-1429
[3]
Osteoporosis markers on low-dose lung cancer screening chest computed tomography scans predict all-cause mortality [J].
Buckens, C. F. ;
van der Graaf, Y. ;
Verkooijen, H. M. ;
Mali, W. P. ;
Isgum, I. ;
Mol, C. P. ;
Verhaar, H. J. ;
Vliegenthart, R. ;
Oudkerk, M. ;
van Aalst, C. M. ;
de Koning, H. J. ;
de Jong, P. A. .
EUROPEAN RADIOLOGY, 2015, 25 (01) :132-139
[4]
Opportunistic screening for osteoporosis on routine computed tomography? An external validation study [J].
Buckens, Constantinus F. ;
Dijkhuis, Gawein ;
de Keizer, Bart ;
Verhaar, Harald J. ;
de Jong, Pim A. .
EUROPEAN RADIOLOGY, 2015, 25 (07) :2074-2079
[5]
Clinician's Guide to Prevention and Treatment of Osteoporosis [J].
Cosman, F. ;
de Beur, S. J. ;
LeBoff, M. S. ;
Lewiecki, E. M. ;
Tanner, B. ;
Randall, S. ;
Lindsay, R. .
OSTEOPOROSIS INTERNATIONAL, 2014, 25 (10) :2359-2381
[6]
Coumans J., 1982, Medicamundi, V27, P125
[7]
Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product [J].
Deak, Paul D. ;
Smal, Yulia ;
Kalender, Willi A. .
RADIOLOGY, 2010, 257 (01) :158-166
[8]
Clinical use of quantitative computed tomography and peripheral quantitative computed tomography in the management of osteoporosis in adults: The 2007 ISCD Official Positions [J].
Engelke, Klaus ;
Adams, Judith E. ;
Armbrecht, Gabriele ;
Augat, Peter ;
Bogado, Cesar E. ;
Bouxsein, Mary L. ;
Felsenberg, Dieter ;
Ito, Masako ;
Prevrhal, Sven ;
Hans, Didier B. ;
Lewiecki, E. Michael .
JOURNAL OF CLINICAL DENSITOMETRY, 2008, 11 (01) :123-162
[9]
Clinical Use of Quantitative Computed Tomography-Based Advanced Techniques in the Management of Osteoporosis in Adults: the 2015 ISCD Official Positions-Part III [J].
Engelke, Klaus ;
Lang, Thomas ;
Khosla, Sundeep ;
Qin, Ling ;
Zysset, Philippe ;
Leslie, William D. ;
Shepherd, John A. ;
Shousboe, John T. .
JOURNAL OF CLINICAL DENSITOMETRY, 2015, 18 (03) :393-407
[10]
Variation in Attenuation in L1 Trabecular Bone at Different Tube Voltages: Caution Is Warranted When Screening for Osteoporosis With the Use of Opportunistic CT [J].
Garner, Hillary W. ;
Paturzo, Michelle M. ;
Gaudier, Gabriela ;
Pickhardt, Perry J. ;
Wessell, Daniel E. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (01) :165-170