Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation

被引:436
作者
Bamberg, Fabian [2 ]
Dierks, Alexander [2 ]
Nikolaou, Konstantin [2 ]
Reiser, Maximilian F. [2 ]
Becker, Christoph R. [2 ]
Johnson, Thorsten R. C. [1 ,2 ]
机构
[1] Univ Munich, D-81377 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Dept Clin Radiol, D-81377 Munich, Germany
关键词
Metal artifacts; Dual energy CT; Computed tomography; Quanta extrapolation; CT; EXPERIENCE;
D O I
10.1007/s00330-011-2062-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to assess the performance and diagnostic value of a dual energy CT approach to reduce metal artefacts in subjects with metallic implants. 31 patients were examined in the area of their metallic implants using a dual energy CT protocol (filtered 140 kVp and 100 kVp spectrum, tube current relation: 3:1). Specific post-processing was applied to generate energies of standard 120 and 140 kVp spectra as well as a filtered 140 kVp spectrum with mean photon energies of 64, 69 and 88 keV, respectively, and an optimized hard spectrum of 95-150 keV. Image quality and diagnostic value were subjectively and objectively determined. Image quality was rated superior to the standard image in 29/31 high energy reconstructions; the diagnostic value was rated superior in 27 patients. Image quality and diagnostic value scores improved significantly from 3.5 to 2.1 and from 3.6 to 1.9, respectively. In several exams decisive diagnostic features were only discernible in the high energy reconstructions. The density of the artefacts decreased from -882 to -341 HU. Dual Energy CT with specific postprocessing can reduce metal artefacts and may significantly enhance diagnostic value in the evaluation of metallic implants.
引用
收藏
页码:1424 / 1429
页数:6
相关论文
共 14 条
[1]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[2]  
GRASER A, INVEST RADIOL, V45, P399
[3]   Dual energy CT characterization of urinary calculi: Initial in vitro and clinical experience [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Bader, Markus ;
Staehler, Michael ;
Haseke, Nicolas ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Stief, Christian G. ;
Becker, Christoph R. .
INVESTIGATIVE RADIOLOGY, 2008, 43 (02) :112-119
[4]   CT SCANS THROUGH METAL SCANNING TECHNIQUE VERSUS HARDWARE COMPOSITION [J].
HARAMATI, N ;
STARON, RB ;
MAZELSPERLING, K ;
FREEMAN, K ;
NICKOLOFF, EL ;
BARAX, C ;
FELDMAN, F .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1994, 18 (06) :429-434
[5]   Evaluation of non-linear blending in dual-energy computed tomography [J].
Holmes, David R., III ;
Fletcher, Joel G. ;
Apel, Anja ;
Huprich, James E. ;
Siddiki, Hassan ;
Hough, David M. ;
Schmidt, Bernhard ;
Flohr, Thomas G. ;
Robb, Richard ;
McCollough, Cynthia ;
Wittmer, Michael ;
Eusemann, Christian .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) :409-413
[6]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[7]  
KRAUSS B, 2010, EUR C RAD 2010, pS201
[8]   Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multidetector CT [J].
Lee, Mi-Jung ;
Kim, Sungjun ;
Lee, Sung-Ah ;
Song, Ho-Taek ;
Huh, Yong-Min ;
Kim, Dae-Hong ;
Han, Seung Hwan ;
Suh, Jin-Suck .
RADIOGRAPHICS, 2007, 27 (03) :791-803
[9]  
THIEME SF, EUR RADIOL, V20, P2882
[10]   Dual-energy CT head bone and hard plaque removal for quantification of calcified carotid stenosis: utility and comparison with digital subtraction angiography [J].
Uotani, Kensuke ;
Watanabe, Yoshiyuki ;
Higashi, Masahiro ;
Nakazawa, Tetsuro ;
Kono, Atsushi K. ;
Hori, Yoshiro ;
Fukuda, Tetsuya ;
Kanzaki, Suzu ;
Yamada, Naoaki ;
Itoh, Toshihide ;
Sugimura, Kazuro ;
Naito, Hiroaki .
EUROPEAN RADIOLOGY, 2009, 19 (08) :2060-2065