Capillary isoelectric focusing with UV-induced fluorescence detection

被引:34
作者
Horká, M
Willimann, T
Blum, M
Nording, P
Friedl, Z
Slais, K
机构
[1] Acad Sci Czech Republ, Inst Analyt Chem, CS-61142 Brno, Czech Republic
[2] Fluka Prod GmbH, CH-9471 Buchs SG, Switzerland
[3] Brno Univ Technol, Fac Chem, Brno 61200, Czech Republic
关键词
isoelectric focusing; detection; electrophoresis; fluorescence detection; proteins;
D O I
10.1016/S0021-9673(00)01069-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Low-molecular-mass fluorescent compounds excitable in the near UV region with suitable acidobasic and electrophoretic properties are suggested as isoelectric point (pI) markers for isoelectric focusing (IEF) with UV photometric and UV excited fluorometric detection. The experimental set-up of capillary IEF with W excited fluorometric detection and properties of new UV-induced fluorescent pi markers are given. The pI values of 18 new pI markers determined independently of IEF methods range from 2.1 to 10.3. The examples of separation of new pi markers together with derivatized proteins by capillary IEF with photometric or fluorometric detection are presented. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 31 条
[1]   BEHAVIOR OF SUBSTITUTED AMINOMETHYLPHENOL DYES IN CAPILLARY ISOELECTRIC-FOCUSING WITH ELECTROOSMOTIC ZONE DISPLACEMENT [J].
CASLAVSKA, J ;
MOLTENI, S ;
CHMELIK, J ;
SLAIS, K ;
MATULIK, F ;
THORMANN, W .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (02) :549-559
[2]   ATLAS OF FLUORESCENCE-SPECTRA AND LIFETIMES OF DYES ATTACHED TO PROTEIN [J].
CHEN, RF ;
SCOTT, CH .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (04) :393-421
[3]   AMINO-ACID ANALYSES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - AN EVALUATION OF THE USEFULNESS OF PRECOLUMN DNS DERIVATIZATION [J].
DEJONG, C ;
HUGHES, GJ ;
VANWIERINGEN, E ;
WILSON, KJ .
JOURNAL OF CHROMATOGRAPHY, 1982, 241 (02) :345-359
[4]  
Foret F., 1993, CAPILLARY ZONE ELECT
[5]   RESOLUTION AND PEAK CAPACITY IN EQUILIBRIUM-GRADIENT METHODS OF SEPARATION [J].
GIDDINGS, JC ;
DAHLGREN, K .
SEPARATION SCIENCE, 1971, 6 (03) :345-&
[6]  
GIDDINGS JC, 1991, UNIFIED SEPARATION S, P180
[7]   IMMOBILIZED STATIONARY PHASES ON THE BASIS OF POLYETHYLENE-GLYCOL [J].
HORKA, M ;
KAHLE, V ;
JANAK, K ;
TESARIK, K .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1985, 8 (05) :259-263
[8]   PERFORMANCE OF REVERSED-PHASE PARALLEL-CURRENT OPEN-TUBULAR LIQUID-CHROMATOGRAPHY COLUMNS AND COMPARISON WITH THEORY [J].
HORKA, M ;
KAHLE, V ;
KREJCI, M ;
SLAIS, K .
JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) :45-52
[9]  
KIRSCHENBAUM PM, 1975, HDB BIOCH MOL BIOL, V2, P383
[10]   Evaluation of pH gradient formation of carrier ampholytes with synthesized isoelectric point markers in capillary isoelectric focusing [J].
Kobayashi, H ;
Aoki, M ;
Suzuki, M ;
Yanagisawa, A ;
Arai, E .
JOURNAL OF CHROMATOGRAPHY A, 1997, 772 (1-2) :137-144