The application of the transient, electromagnetic method in hydrogeophysical surveys

被引:284
作者
Danielsen, JE
Auken, E
Jorgensen, F
Sondergaard, V
Sorensen, KI
机构
[1] Univ Aarhus, HydroGeophys Grp, Dept Earth Sci, DK-8200 Aarhus N, Denmark
[2] Vejle Cty, DK-7100 Vejle, Denmark
[3] Aarhus Cty, Hojbjerg, Denmark
关键词
transient electromagnetic; TEM; coupling; buried valleys; 2D modelling; hydrogeophysics;
D O I
10.1016/j.jappgeo.2003.08.004
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The transient electromagnetic (TEM) method has been used extensively for hydrogeophysical exploration in Denmark for the past decade. Innovative instrumentation combined with multi-dimensional modelling and interpretational insights based on experience gained through numerous case studies have proven to be a successful strategy. In the case study reported here, the combination revealed an unknown and unexpected buried valley complex. Drill hole data: were in good agreement with estimates of both the bearings and depths of valleys defined by the TEM surveys. The Pulled Array Transient Electromagnetic (PATEM) system was built to provide high data density for increased lateral resolution. A High moment Transient Electromagnetic (HiTEM) system was developed for delineation of aquifers to depths up to 300 in. Because both of these systems provide high data density, data quality can be assessed as part of the interpretational strategy. When acquiring TEM measurements in areas as densely populated as the Danish countryside, precautions must be taken to minimize coupling between the TEM system and man-made conductors. Modelling the slope of the flanks of buried valleys has challenged the adequacy of the one-dimensional (I-D) assumption for inversion of TEM data. The study shows that for a valley structure in a low-resistive layer, the I-D assumption is sufficient to track the presence of rather steep slopes. For a valley structure in a high-resistive layer, however, the insensitivity of the TEM method to resistors makes it difficult to determine a slope with a I-D inversion, and only the overall structure is defined. (C) 2003 Elsevier B.V All rights reserved.
引用
收藏
页码:181 / 198
页数:18
相关论文
共 23 条
  • [1] Mapping coastal aquifers by joint inversion of DC and TEM soundings - Three case histories
    Albouy, Y
    Andrieux, P
    Rakotondrasoa, G
    Ritz, M
    Descloitres, M
    Join, JL
    Rasolomanana, E
    [J]. GROUND WATER, 2001, 39 (01) : 87 - 97
  • [2] [Anonymous], 1998, EUR J ENV ENG GEOPHY
  • [3] Arnason K, 1995, P INT S 3 DIM EL, P167
  • [4] AUKEN E, 2001, MUTUALLY CONSTRAINED, P94
  • [5] Inversion of band-limited TEM responses
    Efferso, F
    Auken, E
    Sorensen, KI
    [J]. GEOPHYSICAL PROSPECTING, 1999, 47 (04) : 551 - 564
  • [6] FITTERMAN DV, 1986, GEOPHYSICS, V51, P995, DOI 10.1190/1.1442158
  • [7] INDUCED-POLARIZATION EFFECTS IN TIME-DOMAIN ELECTROMAGNETIC MEASUREMENTS
    FLIS, MF
    NEWMAN, GA
    HOHMANN, GW
    [J]. GEOPHYSICS, 1989, 54 (04) : 514 - 523
  • [8] ON THE INFLUENCE OF 3-D STRUCTURES IN THE INTERPRETATION OF TRANSIENT ELECTROMAGNETIC SOUNDING DATA
    GOLDMAN, M
    TABAROVSKY, L
    RABINOVICH, M
    [J]. GEOPHYSICS, 1994, 59 (06) : 889 - 901
  • [9] TRANSIENT FIELDS OF A CURRENT LOOP SOURCE ABOVE A LAYERED EARTH
    HOVERSTEN, GM
    MORRISON, HF
    [J]. GEOPHYSICS, 1982, 47 (07) : 1068 - 1077
  • [10] Overdeepened Quaternary valleys in the eastern Danish North Sea: morphology and origin
    Huuse, M
    Lykke-Andersen, H
    [J]. QUATERNARY SCIENCE REVIEWS, 2000, 19 (12) : 1233 - 1253