Narrow sample channel injectors for capillary electrophoresis on microchips

被引:108
作者
Zhang, CX [1 ]
Manz, A [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Astra Zeneca SmithKline Beecham Ctr Analyt Sci, Dept Chem, London SW7 2AY, England
关键词
D O I
10.1021/ac010138f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In microchip CE, sample injection is generally achieved through cross, double-tee, or tee injector structures, In these reported approaches, channel width and depth are uniform at the injection intersection. Here, we present cross and tee injectors having narrow sample channels. Using a cross injector with reduced sample channel width, resolution, column efficiency, and sensitivity are remarkably improved, Furthermore, no leakage control is required in both injection and separation phases, making the microchip CE system more user-friendly, Good resolution can also be obtained using tee injectors with nano ri sample channels, which would otherwise be impossible using conventional tee injectors. Using the narrow sample channel tee injector instead of conventional cross and double-tee injectors, the number of resevoirs in multiplexed systems can be reduced to N + 2 (N, the number of paralleled CE systems), the real theoretical limit. The virtues of the novel injectors were demonstrated with poly(dimethylsiloxane)-glass chips incorporating eight parallel CE channels.
引用
收藏
页码:2656 / 2662
页数:7
相关论文
共 36 条
[1]   Degenerate oligonucleotide primed polymerase chain reaction and capillary electrophoretic analysis of human DNA on microchip-based devices [J].
Cheng, J ;
Waters, LC ;
Fortina, P ;
Hvichia, G ;
Jacobson, SC ;
Ramsey, JM ;
Kricka, LJ ;
Wilding, P .
ANALYTICAL BIOCHEMISTRY, 1998, 257 (02) :101-106
[2]   Room temperature bonding of micromachined glass devices for capillary electrophoresis [J].
Chiem, N ;
Lockyear-Shultz, L ;
Andersson, P ;
Skinner, C ;
Harrison, DJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (03) :147-152
[3]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[4]  
Deshpande M, 2000, MESA MG, P339
[5]   MANIPULATION OF SAMPLE FRACTIONS ON A CAPILLARY ELECTROPHORESIS CHIP [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2284-2287
[6]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[7]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[8]   Microfluidic assays of acetylcholinesterase inhibitors [J].
Hadd, AG ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1999, 71 (22) :5206-5212
[9]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[10]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932