Assessing the influence of scanner background noise on auditory processing. I. An fMRI study comparing three experimental designs with varying degrees of scanner noise

被引:89
作者
Gaab, Nadine
Gabrieli, John D. E.
Glover, Gary H.
机构
[1] Stanford Univ, Dept Psychol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
fMRI; auditory cortex; scanner background noise; sparse temporal sampling; clustered volume acquisition;
D O I
10.1002/hbm.20298
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We compared two experimental designs aimed at minimizing the influence of scanner background noise (SBN) on functional MRI (fMRI) of auditory processes with one conventional fMRI design. Ten subjects listened to a series of four one-syllable words and had to decide whether two of the words were identical. This was contrasted with a no-stimulus control condition. All three experimental designs had a duration of similar to 17 min: 1) a behavior interleaved gradients (BIG; Eden et al. [1999] J Magn Reson Imaging 41:13-20) design (repetition time, TR, = 6 s), where stimuli were presented during the SBN-free periods between clustered volume acquisitions (CVA); 2) a sparse temporal sampling technique (STsamp; e.g., Gaab et al., [2003] Neuroimage 19:1417-1426) acquiring only one set of slices following each of the stimulations with a 16-s TR and jittered delay times between stimulus offset and image acquisition; and 3) an event-related design with continuous scanning (ERcont) using the stimulation design of STsamp but with a 2-s TR. The results demonstrated increased signal within Heschl's gyrus for the STsamp and BIG-CVA design in comparison to ERcont as well as differences in the overall functional anatomy among the designs. The possibility to obtain a time course of activation as well as the full recovery of the stimulus- and SBN-induced hemodynamic response function signal and lack of signal suppression from SBN during the STsamp design makes this technique a powerful approach for conducting auditory experiments using fMRI. Practical strengths and limitations of the three auditory acquisition paradigms are discussed.
引用
收藏
页码:703 / 720
页数:18
相关论文
共 103 条
[61]   Cerebellum and speech perception: A functional magnetic resonance imaging study [J].
Mathiak, K ;
Hertrich, I ;
Grodd, W ;
Ackermann, H .
JOURNAL OF COGNITIVE NEUROSCIENCE, 2002, 14 (06) :902-912
[62]  
McJury M, 2000, J MAGN RESON IMAGING, V12, P37, DOI 10.1002/1522-2586(200007)12:1<37::AID-JMRI5>3.0.CO
[63]  
2-I
[64]   ACOUSTIC NOISE-LEVELS GENERATED DURING HIGH-FIELD MR-IMAGING [J].
MCJURY, MJ .
CLINICAL RADIOLOGY, 1995, 50 (05) :331-334
[65]   Acoustic noise concerns in functional magnetic resonance imaging [J].
Moelker, A ;
Pattynama, PMT .
HUMAN BRAIN MAPPING, 2003, 20 (03) :123-141
[66]   Sparse imaging of the auditory oddball task with functional MRI [J].
Müller, BW ;
Stude, P ;
Nebel, K ;
Wiese, H ;
Ladd, ME ;
Forsting, M ;
Jueptner, M .
NEUROREPORT, 2003, 14 (12) :1597-1601
[67]   Controlling the familywise error rate in functional neuroimaging: a comparative review [J].
Nichols, T ;
Hayasaka, S .
STATISTICAL METHODS IN MEDICAL RESEARCH, 2003, 12 (05) :419-446
[68]   Quiet imaging with interleaved spiral read-out [J].
Oesterle, C ;
Hennel, F ;
Hennig, J .
MAGNETIC RESONANCE IMAGING, 2001, 19 (10) :1333-1337
[69]   Processing of audiovisual speech in Broca's area [J].
Ojanen, V ;
Möttönen, R ;
Pekkola, J ;
Jääskeläinen, IP ;
Joensuu, R ;
Autti, T ;
Sams, M .
NEUROIMAGE, 2005, 25 (02) :333-338
[70]   Imaging melody and rhythm processing in young children [J].
Overy, K ;
Norton, AC ;
Cronin, KT ;
Gaab, N ;
Alsop, DC ;
Winner, E ;
Schlaug, G .
NEUROREPORT, 2004, 15 (11) :1723-1726