Disposable screen-printed carbon electrodes for dual Electrochemiluminescence/Amperometric detection: Sequential injection analysis of oxalate

被引:17
作者
Chin, Mei-Hsin [1 ]
Wu, Han [1 ]
Chen, Jyh-Cheng [1 ]
Muthuraman, Govindan [1 ]
Zen, Jyh-Myng [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
electrochemiluminescence; sequential injection analysis; screen-printed electrodes; oxalate;
D O I
10.1002/elan.200703984
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes the development and application of an electrochemical cell specifically designed for disposable screen printed carbon electrodes (SPCE) suitable for simultaneous electrochemiluminescence (ECL) and amperometric detection in sequential injection analysis. The flow system with facility for photomultiplier tube via a fiber optic facing the SPCE is user-friendly and makes the detection process very easy to operate. Instead of the need to constant deliver the chemiluminescence (CL) reagents to the reaction zone, sequential injection analysis allows a considerable reduction in the consumption of the sample and expensive CL reagents (such as Ru(bpy)(3)(2+) salts). The utility of the analyzer was demonstrated for the detection of oxalate based on the ECL reaction with Ru(bpy)(3)(2+). Under optimized conditions, in the presence of 100 mu M Ru(bpy)(3)(2+), the linear ranges of peak current and 3 3 ECL light intensity for oxalate distinctly varied from 10 mu M to 5 mM and 0.1 mu M to 100 mu W, respectively. In other words, the linear detection can be covered over a four-order range with the combination of these two signals.
引用
收藏
页码:2301 / 2306
页数:6
相关论文
共 20 条
[1]   Flow injection analysis system equipped with a newly designed electrochemiluminescent detector and its application for detection of 2-thiouracil [J].
Chi, YW ;
Duan, JP ;
Lin, SD ;
Chen, GN .
ANALYTICAL CHEMISTRY, 2006, 78 (05) :1568-1573
[2]   HIGH-FREQUENCY GENERATION OF ELECTROCHEMILUMINESCENCE AT MICROELECTRODES [J].
COLLINSON, MM ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2576-2582
[3]   Recent applications of electrogenerated chemiluminescence in chemical analysis [J].
Fähnrich, KA ;
Pravda, M ;
Guilbault, GG .
TALANTA, 2001, 54 (04) :531-559
[4]  
FORSTER RJ, 2000, ANAL CHEM, V72, P789
[5]   Analytical applications of tris(2,2′-bipyridyl)ruthenium(III) as a chemiluminescent reagent [J].
Gerardi, RD ;
Barnett, NW ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :1-41
[6]   Mediated electron transfer for electroanalysis:: transport and kinetics in tin films of [Ru (bpy)2PVP10] (ClO4)2 [J].
Hogan, CF ;
Forster, RJ .
ANALYTICA CHIMICA ACTA, 1999, 396 (01) :13-21
[7]   An electrochemical cell coupled with disposable screen-printed electrodes for use in flow injection analysis [J].
Hsu, CT ;
Chung, HH ;
Lyuu, HJ ;
Tsai, DM ;
Kumar, AS ;
Zen, JM .
ANALYTICAL SCIENCES, 2006, 22 (01) :35-38
[8]   A review of recent trends in analytical applications of electrogenerated chemiluminescence [J].
Knight, AW .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (01) :47-62
[9]   MICRORING ELECTRODE OPTICAL WAVE-GUIDE - ELECTROCHEMICAL CHARACTERIZATION AND APPLICATION TO ELECTROGENERATED CHEMILUMINESCENCE [J].
KUHN, LS ;
WEBER, A ;
WEBER, SG .
ANALYTICAL CHEMISTRY, 1990, 62 (15) :1631-1636
[10]   Luminol electrochemiluminescence with screen-printed electrodes for low-cost disposable oxidase-based optical sensors [J].
Leca, B ;
Blum, LJ .
ANALYST, 2000, 125 (05) :789-791