Exogenous sources of Pseudomonas aeruginosa in intensive care unit patients:: Implementation of infection control measures and follow-up with molecular typing

被引:37
作者
Petignat, Christiane
Francioli, Patrick
Nahimana, Immaculee
Wenger, Aline
Bille, Jacques
Schaller, Marie-Denise
Revelly, Jean-Pierre
Zanetti, Giorgio
Blanc, Dominique S.
机构
[1] Univ Lausanne Hosp, Hosp Prevent Med, Lausanne, Switzerland
[2] Univ Lausanne Hosp, Inst Microbiol, Lausanne, Switzerland
[3] Univ Lausanne Hosp, Med Intens Care Unit, Lausanne, Switzerland
[4] Univ Lausanne Hosp, Surg Intens Care Unit, Lausanne, Switzerland
关键词
D O I
10.1086/506409
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
background. In 1998, a study in the intensive care unit ( ICU) of our institution suggested possible transmission of Pseudomonas aeruginosa from faucet to patient and from patient to patient. Infection- control measures were implemented to reduce the degree of P. aeruginosa colonization in faucets, to reduce the use of faucet water in certain patient care procedures, and to reduce the rate of transmission from patient to patient. objective. To evaluate the effect of the control measures instituted in 1999 to prevent P. aeruginosa infection and colonization in ICU patients. design. Prospective, molecular, epidemiological investigation. setting. A 870- bed, university- affiliated, tertiary care teaching hospital. methods. The investigation was performed in a manner identical to the 1998 investigation. ICU patients with a clinical specimen positive for P. aeruginosa were identified prospectively. Swab specimens from the inner part of the ICU faucets were obtained for the culture on 9 occasions between September 1997 and December 2000. All patients and environmental isolates were typed by pulsed- field gel electrophoresis ( PFGE). results. Compared with the 1998 study, in 2000 we found that the annual incidence of ICU patients colonized or infected with P. aeruginosa had decreased by half ( 26.6 patients per 1,000 admissions in 2000 vs 59.0 patients per 1,000 admissions in 1998), although the populations of patients were comparable. This decrease was the result of the decreased incidence of cases in which an isolate had a PFGE pattern identical to that of an isolate from a faucet ( 7.0 cases per 1,000 admissions in 2000, vs 23.6 per 1,000 admissions in 1998) or from another patient ( 6.5 cases per 1,000 admissions in 2000 vs 16.5 cases per 1,000 admissions in 1998), whereas the incidence of cases in which the isolate had a unique PFGE pattern remained nearly unchanged ( 13.1 cases per 1,000 admissions in 2000 vs 15.6 cases per 1,000 admissions in 1998). conclusions These results suggest that infection control measures were effective in decreasing the rate of P. aeruginosa colonization and infection in ICU patients, confirming that P. aeruginosa strains were of exogenous origin in a substantial proportion of patients during the preintervention period.
引用
收藏
页码:953 / 957
页数:5
相关论文
共 21 条
[1]  
ARNOW PM, 1999, HOSPITAL EPIDEMIOLOG, V431, P451
[2]   Multi-resistant Pseudomonas aeruginosa outbreak associated with contaminated tap water in a neurosurgery intensive care unit [J].
Bert, F ;
Maubec, E ;
Bruneau, B ;
Berry, P ;
Lambert-Zechovsky, N .
JOURNAL OF HOSPITAL INFECTION, 1998, 39 (01) :53-62
[3]   Prospective study of nosocomial colonization and infection due to Pseudomonas aeruginosa in mechanically ventilated patients [J].
Berthelot, P ;
Grattard, E ;
Mahul, P ;
Pain, P ;
Jospé, R ;
Venet, C ;
Carricajo, A ;
Aubert, G ;
Ros, A ;
Dumont, A ;
Lucht, F ;
Zéni, F ;
Auboyer, C ;
Bertrand, JC ;
Pozzetto, B .
INTENSIVE CARE MEDICINE, 2001, 27 (03) :503-+
[4]   Faucets as a reservoir of endemic Pseudomonas aeruginosa colonization/infections in intensive care units [J].
Blanc, DS ;
Nahimana, I ;
Petignat, C ;
Wenger, A ;
Bille, J ;
Francioli, P .
INTENSIVE CARE MEDICINE, 2004, 30 (10) :1964-1968
[5]  
Blanc DS, 1997, INFECT CONT HOSP EP, V18, P134
[6]   Characteristics of polyclonal endemicity of Pseudomonas aeruginosa colonization in intensive care units -: Implications for infection control [J].
Bonten, MJM ;
Bergmans, DCJJ ;
Speijer, H ;
Stobberingh, EE .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (04) :1212-1219
[7]   Outbreak of severe Pseudomonas aeruginosa respiratory infections due to contaminated nebulizers [J].
Cobben, NAM ;
Drent, M ;
Jonkers, M ;
Wouters, EFM ;
Vaneechoutte, M ;
Stobberingh, EE .
JOURNAL OF HOSPITAL INFECTION, 1996, 33 (01) :63-70
[8]   MOLECULAR EPIDEMIOLOGY OF PSEUDOMONAS-AERUGINOSA IN AN INTENSIVE-CARE UNIT [J].
DORING, G ;
HORZ, M ;
ORTELT, J ;
GRUPP, H ;
WOLZ, C .
EPIDEMIOLOGY AND INFECTION, 1993, 110 (03) :427-436
[9]   Outbreak of nosocomial urinary tract infections due to Pseudomonas aeruginosa in a paediatric surgical unit associated with tap-water contamination [J].
Ferroni, A ;
Nguyen, L ;
Pron, B ;
Quesne, G ;
Brusset, MC ;
Berche, P .
JOURNAL OF HOSPITAL INFECTION, 1998, 39 (04) :301-307
[10]   RIBOTYPING OF PSEUDOMONAS-AERUGINOSA STRAINS ISOLATED FROM SURGICAL INTENSIVE-CARE PATIENTS [J].
GRUNER, E ;
KROPEC, A ;
HUEBNER, J ;
ALTWEGG, M ;
DASCHNER, F .
JOURNAL OF INFECTIOUS DISEASES, 1993, 167 (05) :1216-1220