Determination of extra virgin olive oil acidity by FIA-titration

被引:44
作者
Mariotti, E [1 ]
Mascini, M [1 ]
机构
[1] Univ Florence, Dipartimento Sanita Pubbl Epidemiol & Chim Analit, I-50121 Florence, Italy
关键词
extra virgin olive oil; FIA titration; acidity degree;
D O I
10.1016/S0308-8146(00)00323-X
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A direct determination of extra virgin olive oil acidity by an automated flow injection titration is proposed. The oil sample (280 mul) is directly injected, without dilution, in the carrier stream, a n-propanol solution flowing at 2 ml/min and containing potassium hydroxide 1 mM as titrant and phenolphthalein 5 10(-5) M as indicator. In the mixing chamber(1.5 mi) the sample mixes and reacts with the carrier stream. By an optical fiber beam, connected to a spectrophotometer set at 562 nm, we are able to appreciate continuously the phenolphthalein absorbance (Abs) decrease. The area of the peak "Delta Abs vs, time" has a linear correlation with the logarithm 1 of the sample acidity. Several extra virgin olive oil samples have been analysed. The correlation curve between the official (O) and proposed methods (P) is P = (0.02 +/-0.02) + (1.02 +/-0.03)O, with r(2) = 0.997 and s(r) = 0.033; the accuracy and precision, expressed as mean error and RSD, are both <5%; the number of samples analysed per hour, the solvent and the sample consumption, in comparison with the official procedure, are respectively 12-60 versus 7-8, 2-10 ml versus 100-150 ml and 0.5 ml versus 10-20 ml. These features and the simple procedure indicate how the proposed method could represent an interesting alternative to the European community official method for the determination of free fatty acids in oil. <(c)> 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:235 / 238
页数:4
相关论文
共 11 条
[1]  
[Anonymous], 1989, FLOW INJECTION ANAL
[2]   Gradient flow titration for the determination of fluoride ion in natural waters [J].
da Conceiçao, AC ;
dos Santos, MMC ;
Gonçalves, MLSS ;
Santos, FJV .
TALANTA, 2000, 50 (06) :1245-1252
[3]   FLOW-INJECTION TITRATION OF CHLORIDE IN FOOD-PRODUCTS WITH A SILVER TUBULAR ELECTRODE BASED ON AN HOMOGENEOUS CRYSTALLINE MEMBRANE [J].
FERREIRA, IMPLVO ;
LIMA, JLFC ;
RANGEL, AOSS .
FOOD CHEMISTRY, 1994, 50 (04) :423-428
[4]   ION SENSITIVE ELECTRODES IN FLOW-INJECTION ANALYSIS - IMPROVED PERFORMANCE AND UNIQUE APPLICATIONS [J].
FRENZEL, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 329 (06) :698-700
[5]   AUTOMATED FLOW-INJECTION SPECTROPHOTOMETRIC NON-AQUEOUS PSEUDOTITRATIONS OF AMINES AND THEIR HYDROHALIDE SALTS [J].
GEORGIOU, CA ;
KOUPPARIS, MA .
ANALYST, 1988, 113 (05) :755-760
[6]   DIRECT AUTOMATIC-DETERMINATION OF FREE ACIDITY IN OILS BY FLOW-INJECTION ANALYSIS [J].
LINARES, P ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1989, 225 (02) :431-436
[7]   Automated flow injection spectrophotometric non-aqueous titrimetric determination of the free fatty acid content of olive oil [J].
Nouros, PG ;
Georgiou, CA ;
Polissiou, MG .
ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) :291-297
[8]   CONTINUOUS-FLOW TITRATION SYSTEM FOR THE GENERATION OF MULTIVARIATE SPECTROPHOTOMETRIC DATA IN THE STUDY OF ACID-BASE EQUILIBRIA [J].
SAURINA, J ;
HERNANDEZCASSOU, S ;
TAULER, R .
ANALYTICA CHIMICA ACTA, 1995, 312 (02) :189-198
[9]   FLOW-INJECTION ANALYSIS IN SOIL RESEARCH AND PLANT ANALYSIS [J].
SCHALLER, K ;
LENHARDT, R ;
WEBER, V ;
EULER, C .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 329 (06) :701-706
[10]   An automated flow-reversal injection liquid-liquid extraction approach to the direct determination of total free fatty acids in olive oils [J].
Zhi, ZL ;
Rios, A ;
Valcarcel, M .
ANALYTICA CHIMICA ACTA, 1996, 318 (02) :187-194