Near infrared determination of Diuron in pesticide formulations

被引:26
作者
Moros, J [1 ]
Armenta, S [1 ]
Garrigues, S [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, Valencia 46100, Spain
关键词
near infrared; pesticide; formulations; agrochemicals;
D O I
10.1016/j.aca.2005.04.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, fast and environmentally friendly near infrared (NIR)-based methodology was developed for Diuron determination in pesticide formulations. This methodology was based on the pesticide extraction with acetonitrile and subsequent transmittance measurement determination by peak area measurement between 2021 and 2047 nm, corrected with a single point baseline established at 2071 nm. The repeatability, as relative standard deviation of five independent analysis of a 15.3 mg g(-1) Diuron standard was 0.03% and the limit of detection 0.013 mg g(-1). The reagent consumption was clearly reduced in front of a chromatographic reference procedure from 39.1 ml acetonitrile per sample, required by liquid chromatography (LC), to 1 ml of acetonitrile consumed for NIR. The sample measurement throughput obtained by the NIR methodology was 120 h(-1), 10 times higher than that obtained by LC (12 h(-1)). It can be concluded that the proposed vibrational method is appropriate for the quality control of pesticide commercial formulations. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:124 / 129
页数:6
相关论文
共 24 条
[1]   Conductometric tyrosinase biosensor for the detection of diuron, atrazine and its main metabolites [J].
Anh, TM ;
Dzyadevych, SV ;
Van, MC ;
Renault, NJ ;
Duc, CN ;
Chovelon, JM .
TALANTA, 2004, 63 (02) :365-370
[2]  
ARMENTA S, IN PRESS ANAL CHEM
[3]   Strategies for constructing the calibration set for a near infrared spectroscopic quantitation method [J].
Blanco, M ;
Romero, MA ;
Alcalà, M .
TALANTA, 2004, 64 (03) :597-602
[4]  
BURNS D, 1992, HDB NEAR INFRARED SP
[5]   Simultaneous determination of phenyl- and sulfonylurea herbicides in water by solid-phase extraction and liquid chromatography with UV diode array or mass spectrometric detection [J].
Carabias-Martínez, R ;
Rodríguez-Gonzalo, E ;
Herrero-Hernández, E ;
Hernández-Méndez, J .
ANALYTICA CHIMICA ACTA, 2004, 517 (1-2) :71-79
[6]   Multiresidue analysis of pesticides in environmental waters by capillary electrophoresis using simultaneous UV and electrochemical detection [J].
Chicharro, M ;
Zapardiel, A ;
Bermejo, E ;
Sánchez, A ;
González, R .
ELECTROANALYSIS, 2004, 16 (04) :311-318
[7]  
*COLL INT PEST AN, 1999, GUID METH VAL PERF S
[8]  
DELINAN C, 2000, VADEMECUM PRODUCTOS
[9]   Fluorescence polarization immunoassay for the insecticide DDT and its metabolites [J].
Eremin, SA ;
Bochkareva, AE ;
Popova, VA ;
Abad, A ;
Manclus, JJ ;
Mercader, JV ;
Montoya, A .
ANALYTICAL LETTERS, 2002, 35 (11) :1835-1850
[10]   Determination of two antifouling booster biocides and their degradation products in marine sediments by high performance liquid chromatography-diode array detection [J].
Gatidou, G ;
Kotrikla, A ;
Thomaidis, NS ;
Lekkas, TD .
ANALYTICA CHIMICA ACTA, 2004, 505 (01) :153-159