Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position

被引:138
作者
Dorr, Lawrence A. [1 ]
Malik, Aamer [1 ]
Wan, Zhinian [1 ]
Long, William T. [1 ]
Harris, Michael [1 ]
机构
[1] Arthritis Inst, Inglewood, CA 90301 USA
关键词
D O I
10.1097/BLO.0b013e3181560c51
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computer navigation has the potential to permit accurate placement of components. We first hypothesized acetabular inclination and anteversion using navigation would be within 5 degrees of postoperative computed tomography scans, then secondly. computer precision would be better than that of surgeons. In the first phase, we obtained postoperative CT scans in 30 hips to ascertain the computer navigation values for inclination and anteversion of the cup. In the second phase, in 99 patients with 101 hips, we determined the surgeon's precision by comparing surgeons' blind estimates for trial cup position with computer navigation values. The navigation precision for inclination was 4.4 degrees with a bias of 0.03 degrees and for anteversion was 4.1 degrees with a bias of 0.73 degrees. The experienced surgeons precision was 11.5 degrees for inclination and 12.3 degrees for anteversion, whereas the less experienced surgeons' precision was 13.1 degrees for inclination and 13.9 degrees for anteversion. The data supported the first hypothesis as computer navigation had a bias for inclination and anteversion of less than V with precision less than 5 degrees. The precision of computer navigation was better than that of surgeons. This imageless computer navigation system allows more accurate acetabular component placement.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 40 条
[1]
ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]
*ASTM, 2002, ANN BOOK ASTM STAND, pE177
[3]
*ASTM, 1992, STAND PRACT COND INT, pE691
[4]
Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty [J].
Barrack, RL ;
Lavernia, C ;
Ries, M ;
Thornberry, R ;
Tozakoglou, E .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (04) :569-+
[5]
RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP [J].
CALLAGHAN, JJ ;
SALVATI, EA ;
PELLICCI, PM ;
WILSON, PD ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1074-1085
[6]
Charnley J, 1973, CLIN ORTHOP RELAT R, V95, P9
[7]
The Harris-Galante porous-coated acetabular component with screw fixation - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :66-73
[8]
D'Antonio JA, 2001, CLIN ORTHOP RELAT R, P101
[9]
The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[10]
Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364