Differential mobility spectrometer: Model of operation

被引:147
作者
Krylov, E. V. [1 ]
Nazarov, E. G. [1 ]
Miller, R. A. [1 ]
机构
[1] Sionex Corp, Bedford, MA 01730 USA
关键词
differential mobility spectrometer; FAIMS; spectral peak; modeling;
D O I
10.1016/j.ijms.2007.07.003
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Differential mobility spectrometry is a powerful tool used in a rapidly growing number and variety of applications for detection and characterization of gas-phase ions. In this paper a comprehensive mathematical model of the apparatus implementing the differential mobility spectrometry method is described. For completeness the mathematical theory of the method is provided. The model focuses on the analytical parameters of the differential mobility spectrometry instrument. The influence of instrumental parameters (carrier gas flow rate, separating field amplitude and waveform, filter gap size and geometry) and ion properties (diffusion, mobility and electric field mobility dependence) on the spectral peak characteristics (position, height and width) is examined. Both planar and coaxial instruments are covered in the same mathematical model. The model is extensively validated using published and our own experimental data. Proposed model is demonstrated to be in a good quantitative agreement with experimental data. This model explains all observed phenomena and predicts new ones such as high field focusing. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:76 / 85
页数:10
相关论文
共 27 条
[1]  
BOHRINGER H, 1987, INT J MASS SPECTROM, V81, P81
[2]   Mathematical analysis of ion motion in a gas subjected to an alternating-sign periodic asymmetric-waveform electric field [J].
Buryakov, I. A. .
TECHNICAL PHYSICS, 2006, 51 (09) :1121-1126
[3]   A NEW METHOD OF SEPARATION OF MULTI-ATOMIC IONS BY MOBILITY AT ATMOSPHERIC-PRESSURE USING A HIGH-FREQUENCY AMPLITUDE-ASYMMETRIC STRONG ELECTRIC-FIELD [J].
BURYAKOV, IA ;
KRYLOV, EV ;
NAZAROV, EG ;
RASULEV, UK .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 128 (03) :143-148
[4]   Qualitative analysis of trace constituents by ion mobility increment spectrometer [J].
Buryakov, IA .
TALANTA, 2003, 61 (03) :369-375
[5]   Detection of explosive vapors in the air using an ion drift nonlinearity spectrometer [J].
Buryakov, IA ;
Kolomiets, YN ;
Luppu, BV .
JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (04) :336-340
[6]  
BURYAKOV IA, 1989, Patent No. 1485808
[7]  
BURYAKOV IA, 1999, CHEM ANAL ENV, P113
[8]  
CARNAHAN B, 1996, P INT C ADV INSTR CO, P87
[9]   COMPARISON OF THE NEGATIVE REACTANT IONS FORMED IN THE PLASMA CHROMATOGRAPH BY NITROGEN, AIR, AND SULFUR-HEXAFLUORIDE AS THE DRIFT GAS WITH AIR AS THE CARRIER GAS [J].
CARR, TW .
ANALYTICAL CHEMISTRY, 1979, 51 (06) :705-711
[10]   Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas [J].
Eiceman, GA ;
Krylov, EV ;
Nazarov, EG ;
Miller, RA .
ANALYTICAL CHEMISTRY, 2004, 76 (17) :4937-4944