An improved algorithm for anisotropic nonlinear diffusion for denoising cryo-tomograms

被引:126
作者
Fernández, JJ [1 ]
Li, S
机构
[1] Univ Almeria, Dept Comp Architecture & Elect, Almeria 04120, Spain
[2] MRC, Mol Biol Lab, Cambridge CB2 2QH, England
基金
英国医学研究理事会;
关键词
electron tomography; denoising; anisotropic nonlinear difrusion;
D O I
10.1016/j.jsb.2003.09.010
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Cryo-electron tomography is an imaging technique with an unique potential for visualizing large complex biological specimens. It ensures preservation of the biological material but the resulting cryotomograms are extremely noisy. Sophisticated denoising techniques are thus essential for allowing the visualization and interpretation of the information contained in the cryotomograms. Here a software tool based on anisotropic nonlinear diffusion is described for filtering cryotomograms. The approach reduces local noise and meanwhile enhances both curvilinear and planar structures. In the program a novel solution of the partial differential equation has been implemented, which allows a reliable estimation of derivatives and, furthermore, reduces computation time and memory requirements. Several criteria have been included to automatically select the optimal stopping time. The behaviour of the denoising approach is tested for visualizing filamentous structures in cryotomograms. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:152 / 161
页数:10
相关论文
共 21 条
[2]   Electron tomography of molecules and cells [J].
Baumeister, W ;
Grimm, R ;
Walz, J .
TRENDS IN CELL BIOLOGY, 1999, 9 (02) :81-85
[3]   Electron tomography: towards visualizing the molecular organization of the cytoplasm [J].
Baumeister, W .
CURRENT OPINION IN STRUCTURAL BIOLOGY, 2002, 12 (05) :679-684
[4]   FhuA-mediated phage genome transfer into liposomes:: A cryo-electron tomography study [J].
Böhm, J ;
Lambert, O ;
Frangakis, AS ;
Letellier, L ;
Baumeister, W ;
Rigaud, JL .
CURRENT BIOLOGY, 2001, 11 (15) :1168-1175
[5]   Wavelet transform filtering and nonlinear anisotropic diffusion assessed for signal reconstruction performance on multidimensional biomedical data [J].
Frangakis, AS ;
Stoschek, A ;
Hegerl, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (02) :213-222
[6]   Noise reduction in electron tomographic reconstructions using nonlinear anisotropic diffusion [J].
Frangakis, AS ;
Hegerl, R .
JOURNAL OF STRUCTURAL BIOLOGY, 2001, 135 (03) :239-250
[7]  
Frank J., 1992, ELECT TOMOGRAPHY 3 D
[8]   Electron tomography of ice-embedded prokaryotic cells [J].
Grimm, R ;
Singh, H ;
Rachel, R ;
Typke, D ;
Zillig, W ;
Baumeister, W .
BIOPHYSICAL JOURNAL, 1998, 74 (02) :1031-1042
[9]   Prospects of electron cryotomography to visualize macromolecular complexes inside cellular compartments:: implications of crowding [J].
Grünewald, K ;
Medalia, O ;
Gross, A ;
Steven, AC ;
Baumeister, W .
BIOPHYSICAL CHEMISTRY, 2003, 100 (1-3) :577-591
[10]  
Jahne B., 1999, HDB COMPUTER VISION, V2, P125