Toward a final design for the Birmingham boron neutron capture therapy neutron beam

被引:9
作者
Allen, DA [1 ]
Beynon, TD
Green, S
James, ND
机构
[1] Univ Birmingham, Sch Phys & Astron, Birmingham B15 2TT, W Midlands, England
[2] Queen Elizabeth Hosp, Dept Med Phys, Birmingham B15 2TH, W Midlands, England
[3] Univ Birmingham, CRC, Inst Canc Studies, Birmingham B15 2TT, W Midlands, England
关键词
BNCT; accelerator; Monte Carlo; epithermal neutrons; MCNP;
D O I
10.1118/1.598480
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper is concerned with the proposed Birmingham accelerator-based epithermal neutron beam for boron neutron capture therapy (BNCT). Details of the final moderator design, such as beam delimiter, shield, and beam exit surface shape are considered. Monte Carlo radiation transport simulations with a head and body phantom have shown that a simple flat moderator beam exit surface is preferable to the previously envisioned spherical design. Dose rates to individual body organs during treatment have been calculated using a standard MIRD phantom. We have shown that a simple polyethylene shield, doped with natural lithium, is sufficient to provide adequate protection to the rest of the body during head irradiations. The effect upon the head phantom dose distributions of the use of such a shield to delimit the therapy beam has been evaluated. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00801-9].
引用
收藏
页码:77 / 82
页数:6
相关论文
共 16 条
[1]   Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy [J].
Allen, DA ;
Beynon, TD ;
Green, S .
MEDICAL PHYSICS, 1999, 26 (01) :71-76
[2]   A DESIGN STUDY FOR AN ACCELERATOR-BASED EPITHERMAL NEUTRON BEAM FOR BNCT [J].
ALLEN, DA ;
BEYNON, TD .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) :807-821
[3]  
ALLEN DA, 1997, EXCERPTA MED INT C S, V1132
[4]  
Briesmeister JF, 1993, LA12625M LOS AL NAT
[5]  
CAPALA J, 1997, EXCERPTA MED INT C S, V1132, P51
[6]  
CASWELL RS, 1982, INT J APPL RADIAT IS, V33, P1227, DOI 10.1016/0020-708X(82)90246-0
[7]   DERIVATIONS OF RELATIVE BIOLOGICAL EFFECTIVENESS FOR THE HIGH-LET RADIATIONS PRODUCED DURING BORON NEUTRON-CAPTURE IRRADIATIONS OF THE 9L RAT GLIOSARCOMA IN-VITRO AND IN-VIVO [J].
CODERRE, JA ;
MAKAR, MS ;
MICCA, PL ;
NAWROCKY, MM ;
LIU, HYB ;
JOEL, DD ;
SLATKIN, DN ;
AMOLS, HI .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (05) :1121-1129
[8]  
*ICRP, 1971, ICRP PUBL S, V15
[9]  
ICRP, 1991, Report No. 60
[10]  
ICRP ( International Commission On Radiological Protection, 1975, 23 ICRP, V23