Non-invasive quantitative assessment of the content of pharmaceutical capsules using transmission Raman spectroscopy

被引:95
作者
Eliasson, Charlotte [1 ]
Macleod, Neil A. [1 ]
Jayes, Linda C. [2 ]
Clarke, Fiona C. [2 ]
Hammond, Stephen V. [2 ]
Smith, Mark R. [2 ]
Matousek, Pavel [1 ]
机构
[1] Rutherford Appleton Lab, Sci & Technol Facil Council, Cent Laser Facil, Didcot OX11 0QX, Oxon, England
[2] Pfizer Ltd, Proc Analyt Support Grp, Sandwich CT13 9NJ, Kent, England
基金
英国工程与自然科学研究理事会;
关键词
Raman; PAT; pharmaceutical; transmission; bulk;
D O I
10.1016/j.jpba.2008.01.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study demonstrates how transmission Raman spectroscopy can be used in the quantitative, non-invasive probing of the bulk content of production line relevant pharmaceutical products contained within capsules with a strong interfering Raman signal (principally TiO2). This approach is particularly beneficial in situations where the conventional Raman backscattering method is hampered or fails due to excessive Raman or fluorescence signals emanating from surface layers (capsule or coating) that pollute the much weaker subsurface Raman signals. In these feasibility experiments the interfering surface Raman signal was effectively suppressed, relative to the Raman signal of the. internal content, by a factor of 33, in the transmission geometry in comparison with the conventional backscattering Raman approach. In conjunction with the superior bulk probing ability of the transmission Raman geometry, which effectively removes the sub-sampling problem inherent to conventional Raman spectroscopy, and multivariate analysis (principal component analysis (PCA), partial least squares (PLS) and classical least squares (CLS) regression), this provides an analytical tool well suited for rapid control monitoring applications in the pharmaceutical industry. The measured relative root mean square error of prediction (RMSEP) of the concentration of the active pharmaceutical ingredient (API) was 1.2 and 1.8% with 5 and 1 s acquisition times, respectively. Crown Copyright (c) 2008 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:221 / 229
页数:9
相关论文
共 31 条
[1]   Composition profiling of seized ecstasy tablets by Raman spectroscopy [J].
Bell, SEJ ;
Burns, DT ;
Dennis, AC ;
Matchett, LJ ;
Speers, JS .
ANALYST, 2000, 125 (10) :1811-1815
[2]   Confocal Raman-spectroscopy: Analytical approach to solid dispersions and mapping of drugs [J].
Breitenbach, J ;
Schrof, W ;
Neumann, J .
PHARMACEUTICAL RESEARCH, 1999, 16 (07) :1109-1113
[3]   On-line analysis using Raman spectroscopy for process control during the manufacture of titanium dioxide [J].
Clegg, IM ;
Everall, NJ ;
King, B ;
Melvin, H ;
Norton, C .
APPLIED SPECTROSCOPY, 2001, 55 (09) :1138-1150
[4]   Chemometric quantitation of the active substance (containing CN) in a pharmaceutical tablet using near-infrared (NIR) transmittance and NIR FT-Raman spectra [J].
Dyrby, M ;
Engelsen, SB ;
Norgaard, L ;
Bruhn, M ;
Lundsberg-Nielsen, L .
APPLIED SPECTROSCOPY, 2002, 56 (05) :579-585
[5]   Deep subsurface Raman spectroscopy of turbid media by a defocused collection system [J].
Eliasson, C. ;
Claybourn, M. ;
Matousek, P. .
APPLIED SPECTROSCOPY, 2007, 61 (10) :1123-1127
[6]   Noninvasive authentication of pharmaceutical products through packaging using spatially offset Raman spectroscopy [J].
Eliasson, Charlotte ;
Matousek, Pavel .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1696-1701
[7]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1193-1202
[8]   Application of on-line Raman spectroscopy for characterizing relationships between drug hydration state and tablet physical stability [J].
Hausman, DS ;
Cambron, RT ;
Sakr, A .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2005, 299 (1-2) :19-33
[9]   Wavelength interval selection in multicomponent spectral analysis by moving window partial least-squares regression with applications to mid-infrared and hear-infrared spectroscopic data [J].
Jiang, JH ;
Berry, RJ ;
Siesler, HW ;
Ozaki, Y .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3555-3565
[10]   Characterization of different laser irradiation methods for quantitative Raman tablet assessment [J].
Johansson, J ;
Pettersson, S ;
Folestad, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) :510-516