摘要
Precise and accurate biomechanical reconstruction during total hip arthroplasty (THA) is essential for durable long-term survivorship. Accurate fit of cementless hip implants is also crucial to reduce micromotion between the bone-implant interfaces to allow for stable osseointegration. Robotic technology aims to minimize potential human errors and improve implant alignment and fit, and address persisting concerns with modern-day cementless THA. Although robotic THA dates back to the early 1990s, concerns with increased operating times, costs, and complications led to its withdrawal. However, semi-active systems have renewed interest in robot-assisted joint arthroplasty. We reviewed the current technology, its potential benefits, and the reported clinical and radiographic outcomes. Early evidence suggests that robotic use may lead to more accurate reconstruction of radiographic parameters, such as implant positioning, fit, center-of-rotation, and leg-length discrepancy. Further research is needed to determine if these will translate into better outcomes and improved implant longevity to justify increased costs.
引用
收藏
页码:47 / 56
页数:10
相关论文
共 46 条
[1]
Robots in orthopaedic surgery - Past, present, and future [J].
Bargar, William L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) :31-36
[2]
Bargar WL, 1998, CLIN ORTHOP RELAT R, P82
[3]
The John Charnley Award Risk Factors for Cup Malpositioning Quality Improvement Through a Joint Registry at a Tertiary Hospital [J].
Callanan, Mark C. ;
Jarrett, Bryan ;
Bragdon, Charles R. ;
Zurakowski, David ;
Rubash, Harry E. ;
Freiberg, Andrew A. ;
Malchau, Henrik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :319-329
[4]
Causes and Patterns of Aborting a Robot-Assisted Arthroplasty [J].
Chun, Young Soo ;
Kim, Kang Il ;
Cho, Yoon Je ;
Kim, Yoon Hyuk ;
Yoo, Myung Chul ;
Rhyu, Kee Hyung .
JOURNAL OF ARTHROPLASTY, 2011, 26 (04) :621-625
[5]
Davey S. M., 2011, Journal of Medical Engineering & Technology, V35, P139, DOI 10.3109/03091902.2011.554596
[6]
Robotic control in knee joint replacement surgery [J].
Davies, B. L. ;
Rodriguez y Baena, F. M. ;
Barrett, A. R. W. ;
Gomes, M. P. S. F. ;
Harris, S. J. ;
Jakopec, M. ;
Cobb, J. P. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H1) :71-80
[7]
Comparison of Robotic-assisted and Conventional Acetabular Cup Placement in THA: A Matched-pair Controlled Study [J].
Domb, Benjamin G. ;
El Bitar, Youssef F. ;
Sadik, Adam Y. ;
Stake, Christine E. ;
Botser, Itamar B. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (01) :329-336
[8]
A Comparison of Surgeon Estimation and Computed Tomographic Measurement of Femoral Component Anteversion in Cementless Total Hip Arthroplasty [J].
Dorr, Lawrence D. ;
Wan, Zhinian ;
Malik, Aamer ;
Zhu, Jinjun ;
Dastane, Manish ;
Deshmane, Prashant .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (11) :2598-2604
[9]
Combined Anteversion Technique for Total Hip Arthroplasty [J].
Dorr, Lawrence D. ;
Malik, Aamer ;
Dastane, Manish ;
Wan, Zhinian .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) :119-127
[10]
Dorr LD, 2009, ORTHOPEDICS, V9, P32