The indeterminate CT pulmonary angiogram: Imaging characteristics and patient clinical outcome

被引:136
作者
Jones, SE [1 ]
Wittram, C [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
D O I
10.1148/radiol.2371041520
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To retrospectively review imaging characteristics of indeterminate computed tomographic (CT) pulmonary angiograms for pulmonary embolism (PE) and patient outcome. MATERIALS AND METHODS: Investigational review board approval was obtained, informed consent was waived, and the study was HIPAA compliant. Retrospective review of 3612 CT pulmonary angiography reports created between July 1, 2001, and July 1, 2003, was performed with a keyword search for "indeterminate," "nondiagnostic," or "inadequate" (thereafter, all defined as "indeterminate") and yielded studies from 237 patients (mean age, 57 years; 117 men, 120 women). Randomly selected diagnostic studies were used to form a control group of 25 subjects (mean age, 64 years; eight men, 17 women). Electronic medical records were reviewed for follow-up imaging (repeat CT pulmonary angiography, conventional pulmonary angiography, ventilation-perfusion scintigraphy, or lower-extremity ultrasonography [US]), use of anticoagulation, placement of inferior vena cava (IVC) filters, clinical outcomes, and comments reqarding indeterminate reading of CT angiograms. Studies (in patients and control subjects) were reviewed for PE, contrast attenuation in the main pulmonary artery (MPA), motion artifacts, image noise, and flow artifacts. Findings were compared with two-sample t tests assuming unequal variance. RESULTS: The cause cited for indeterminism was most often motion (74%), followed by poor contrast enhancement (40%). Contrast attenuation in the MPA was 245 HU +/- 80 (standard deviation) in patients and 339 HU 88 in control subjects (P <.001). Only 46% of indeterminate studies met institutional criteria for adequate contrast attenuation in the MPA. Rereview of studies demonstrated five missed PEs. A total of 81 patients (33%) underwent follow-up imaging within 5 days, with one positive pulmonary angiograrn and four positive lower-limb US scans. Reread or follow-up images depicted thromboembolic disease in 4.2% of patients. Nineteen patients (8%) with indeterminate final result were treated for thromboembolic disease with either anticoagulation or IVC filters. Reports on 22% of indeterminate studies contained recommendations for follow-up imaging, and those recommendations nonsignificantly increased the rate for those examinations from 13% to 19%. Review of discharge summaries showed 22% of studies are clinically interpreted as negative. CONCLUSION: The two major causes of indeterminism are motion artifacts and poor contrast enhancement.(c) RSNA, 2005.
引用
收藏
页码:329 / 337
页数:9
相关论文
共 15 条
[11]   The negative predictive value of spiral computed tomography for the diagnosis of pulmonary embolism in patients with nondiagnostic ventilation-perfusion scans [J].
Ost, D ;
Rozenshtein, A ;
Saffran, L ;
Snider, A .
AMERICAN JOURNAL OF MEDICINE, 2001, 110 (01) :16-21
[12]   Clinical value of thin collimation in the diagnostic workup of pulmonary embolism [J].
Remy-Jardin, M ;
Remy, J ;
Baghaie, F ;
Fribourg, M ;
Artaud, D ;
Duhamel, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) :407-411
[13]   Prospective comparison of helical CT with angiography in pulmonary embolism: global and selective vascular territory analysis. Interobserver agreement [J].
Ruiz, Y ;
Caballero, P ;
Caniego, JL ;
Friera, A ;
Olivera, MJ ;
Tagarro, D ;
Alvarez-Sala, R .
EUROPEAN RADIOLOGY, 2003, 13 (04) :823-829
[14]  
VREIM CE, 1990, JAMA-J AM MED ASSOC, V263, P2753
[15]   Trends in thoracic radiology over a decade at a large academic medical center [J].
Wittram, C ;
Meehan, MJ ;
Halpern, EF ;
Shepard, JAO ;
McLoud, TC ;
Thrall, JH .
JOURNAL OF THORACIC IMAGING, 2004, 19 (03) :164-170