Error detection and measurement in glucose monitors

被引:25
作者
Johnson, RN [1 ]
Baker, JR [1 ]
机构
[1] Natl Womens Hosp, Dept Clin Biochem, Auckland 3, New Zealand
关键词
blood glucose self-monitoring; quality control; blood chemical analysis;
D O I
10.1016/S0009-8981(01)00433-8
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
In a quality review of glucose monitors, we measured the inaccuracy and imprecision of 26 systems. In each case, measurements on at least 50 capillary specimens from diabetic patients were compared with results from capillary blood that had been deproteinized and assayed with hexokinase. We also tested the monitors with commercial control solutions. In patients' specimens having a mean blood glucose concentration of about 9 mmol/l, the bias of the 26 monitors ranged from -5.1 to +20.1% (median = +7.5%). Imprecision of the monitors with blood specimens gave coefficients of variation (CV) ranging from 4.5% to 22.8% (median = 8.7%) at the mean glucose concentration. A control solution for the monitors gave a glucose concentration of 7.6-13.6 mmol /1 (median = 9.2 mmol/l) with CV that varied from 1.7 to 19.8% (median = 4.7%). While the means and CV's of the control were significantly correlated with bias and imprecision of the blood specimens, much of the variance remained unexplained (for bias, r(2) = 0.17; for imprecision, r(2) = 0.43). We conclude that a common basis for calibration could remove a significant component of variation and that control solutions may give a false impression of analytical performance. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 11 条
[1]  
[Anonymous], 1987, DIABETES CARE, V10, P95
[2]  
HAVLIN C E, 1991, Clinical Diabetes, V9, P92
[3]  
JOHN R, 1998, LANCET, V352, P837
[4]   Accuracy of devices used for self-monitoring of blood glucose [J].
Johnson, RN ;
Baker, JR .
ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 :68-74
[5]   Analytical error of home glucose monitors: a comparison of 18 systems [J].
Johnson, RN ;
Baker, JR .
ANNALS OF CLINICAL BIOCHEMISTRY, 1999, 36 :72-79
[6]   NEW APPROACH TO TECHNICAL AND CLINICAL-EVALUATION OF DEVICES FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
KOSCHINSKY, T ;
DANNEHL, K ;
GRIES, FA .
DIABETES CARE, 1988, 11 (08) :619-629
[7]  
MOLITCH ME, 1994, DIABETES CARE, V17, P81
[8]   THE EFFECT OF INTENSIVE TREATMENT OF DIABETES ON THE DEVELOPMENT AND PROGRESSION OF LONG-TERM COMPLICATIONS IN INSULIN-DEPENDENT DIABETES-MELLITUS [J].
SHAMOON, H ;
DUFFY, H ;
FLEISCHER, N ;
ENGEL, S ;
SAENGER, P ;
STRELZYN, M ;
LITWAK, M ;
WYLIEROSETT, J ;
FARKASH, A ;
GEIGER, D ;
ENGEL, H ;
FLEISCHMAN, J ;
POMPI, D ;
GINSBERG, N ;
GLOVER, M ;
BRISMAN, M ;
WALKER, E ;
THOMASHUNIS, A ;
GONZALEZ, J ;
GENUTH, S ;
BROWN, E ;
DAHMS, W ;
PUGSLEY, P ;
MAYER, L ;
KERR, D ;
LANDAU, B ;
SINGERMAN, L ;
RICE, T ;
NOVAK, M ;
SMITHBREWER, S ;
MCCONNELL, J ;
DROTAR, D ;
WOODS, D ;
KATIRGI, B ;
LITVENE, M ;
BROWN, C ;
LUSK, M ;
CAMPBELL, R ;
LACKAYE, M ;
RICHARDSON, M ;
LEVY, B ;
CHANG, S ;
HEINHEINEMANN, M ;
BARRON, S ;
ASTOR, L ;
LEBECK, D ;
BRILLON, D ;
DIAMOND, B ;
VASILASDWOSKIN, A ;
LAURENZI, B .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (14) :977-986
[9]   Effect of intensive blood-glucose control with metformin on complications in overweight patients with type 2 diabetes (UKPDS 34) [J].
Turner, RC ;
Holman, RR ;
Stratton, IM ;
Cull, CA ;
Matthews, DR ;
Manley, SE ;
Frighi, V ;
Wright, D ;
Neil, A ;
Kohner, E ;
McElroy, H ;
Fox, C ;
Hadden, D .
LANCET, 1998, 352 (9131) :854-865
[10]   THE YELLOW-SPRINGS ANALYZER GIVES LOWER RESULTS THAN OTHER GLUCOSE-OXIDASE METHODS OF GLUCOSE MEASUREMENT [J].
UNWIN, N ;
SKILLEN, A ;
ALBERTI, KGMM .
ANNALS OF CLINICAL BIOCHEMISTRY, 1995, 32 :329-331