A change in treatment process with a modern record and verify system

被引:13
作者
Klein, EE [1 ]
Drzymala, RE [1 ]
Williams, R [1 ]
Westfall, LA [1 ]
Purdy, JA [1 ]
机构
[1] Washington Univ, Radiat Oncol Ctr, Edward Mallinckrodt Inst Radiol, Sch Med, St Louis, MO 63110 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1998年 / 42卷 / 05期
关键词
radiation therapy; record and verify; R & V; quality assurance;
D O I
10.1016/S0360-3016(98)00252-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: With the introduction of new treatment devices, such as a multileaf collimator (MLC) and dynamic wedge (DW), therapists have an increased responsibility to ensure correct treatment. Simultaneously, three-dimensional treatment planning (3DTP) has led to an increased number of portals and table movements. To counteract this challenge and maintain efficiency, a comprehensive record and verify (R&V) system is mandatory. We evaluated a commercial system (Varis) for reliability, ease of use, efficiency, and integration with our planning systems. Methods and Materials: Some key elements of the Varis system are: integration of MLC and DW; auto setup for MLC, jaw, collimator,gantry, and limited table parameters; direct download of simulation beam data; and a regimented field scheduling system that prescribes all beam data for particular fractions. Evaluation of the system was driven by treatment time analysis, error rates, and an increased workload. These issues were governed by how we disseminated duties and how the system accommodated or changed our processes. Results: Most data entry is performed by our dosimetry staff. Data can be downloaded from the simulator, but more patients now move from CT simulation and/or 3DTP to the treatment machine. Varis does not link to these systems. The physics staff confirms all entries to correct data entry errors. The workload for dosimetrists increased by an average of 8 minutes/patient entry; physics time increased by 7 minutes/patient entry; the weekly electronic chart check takes approximately 3 minutes/patient. Therapists who used Varis efficiently showed a slight decrease in treatment times, attributed to MLC integration and auto-setup. Some therapists experienced a decrease in efficiency, because of unfamiliarity and excess intervention. On a positive note, notable events have decreased by a factor of 10 since full initiation. Unfortunately, the remaining errors are often the result of a therapist relying on incorrect electronic information. Conclusion: The Varis R&V system has had an impact on our clinic's process and efficiency. Checking of all beam data and related field scheduling have helped reduce errors and misconceptions. We feel a dual-energy machine can be operated with two experienced therapists and an up-to-date R&V system more accurately and efficiently than with three therapists working without an integrated R&V. We anticipate future Varis releases will further promote efficiency and accuracy. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:1163 / 1168
页数:6
相关论文
共 8 条
[1]   EXPERIENCE WITH COMPUTER MONITORING, VERIFICATION AND RECORD KEEPING IN RADIOTHERAPY PROCEDURES USING A CLINAC-4 [J].
FREDRICKSON, DH ;
KARZMARK, CJ ;
RUST, DC ;
TUSCHMAN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 (03) :415-418
[2]   A quality assurance program for ancillary high technology devices on a dual-energy accelerator [J].
Klein, EE ;
Low, DA ;
Maag, D ;
Purdy, JA .
RADIOTHERAPY AND ONCOLOGY, 1996, 38 (01) :51-60
[3]   Multiple machine implementation of enhanced dynamic wedge [J].
Klein, EE ;
Gerber, R ;
Zhu, XR ;
Oehmke, F ;
Purdy, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (04) :977-985
[4]   Clinical implementation of a commercial multileaf collimator: Dosimetry, networking, simulation, and quality assurance [J].
Klein, EE ;
Harms, WB ;
Low, DA ;
Willcut, V ;
Purdy, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1195-1208
[5]   HUMAN ERRORS IN DATA TRANSFER DURING THE PREPARATION AND DELIVERY OF RADIATION TREATMENT AFFECTING THE FINAL RESULT - GARBAGE IN, GARBAGE OUT [J].
LEUNENS, G ;
VERSTRAETE, J ;
VANDENBOGAERT, W ;
VANDAM, J ;
DUTREIX, A ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1992, 23 (04) :217-222
[6]   Novel method to plan, administer, and verify craniospinal axis irradiation [J].
Michalski, JM ;
Gerber, R ;
Klein, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02) :334-334
[7]  
PODMANICZKY KC, 1985, INT J RADIAT ONCOL, V11, P1520
[8]   A SYSTEM FOR THE QUALITY AUDIT OF TREATMENT DOSE DELIVERY IN RADIOTHERAPY [J].
WILLIAMS, JR ;
BRADNAM, MS ;
MCCURRACH, GM ;
DEEHAN, C ;
JOHNSTON, S .
RADIOTHERAPY AND ONCOLOGY, 1991, 20 (03) :197-202