摘要
Continuous flow injection and UV spectrophotometric detection have been proposed for simultaneous determination of the two binary mixtures, butylated hydroxytoluene (BHT)/n-propyl gallate (n-PG) and butylated hydroxytoluene (BHT)/butylated hydroxyanisole (BHA), in food and cosmetics samples. The method is based on the different residence times of each antioxidant when the flow cell is packed to a height of 25 mm with silica C-18 using methanol-water 50:50% (v/v) as a carrier with a flow rate of 1.25 and 1.10ml min(-1) respectively. The determination of each antioxidant is based on the measurement of its absorbance at its maximum wavelengths using a DAD detector at 30 and 180 s for the mixture n-PG-BHT and 90 and 220 s for BHA-BHT. Calibration graphs were linear over the range 10.0-300.0 mug ml(-1) for each antioxidant in both mixtures. The relative standard deviations were 2.5% for BHT and 2.0% for the co-existing antioxidant. Resolution of the n-PG-BHT mixture in ratios between 1:8 and 8:1 and the BHA-BHT mixture in ratios between 1: 10 and 10: 1 is possible. The method was applied to the determination of both antioxidants in fat foods and cosmetics samples with recoveries ranging between 10 1 and 105%. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 25 条
[1]   Simultaneous stopped-flow determination of butylated hydroxyanisole and propyl gallate using a T-format luminescence spectrometer [J].
Aguilar-Caballos, MP ;
Gómez-Hens, A ;
Pérez-Bendito, D .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (02) :312-317
[2]   Simultaneous kinetic determination of butylated hydroxyanisole and propyl gallate by coupling stopped-flow mixing technique and diode-array detection [J].
AguilarCaballos, MP ;
GomezHens, A ;
PerezBendito, D .
ANALYTICA CHIMICA ACTA, 1997, 354 (1-3) :173-179
[3]  
[Anonymous], 1988, ANALYST, V113, P1469
[4]  
[Anonymous], 1978, SPECTROCHIM ACTA, VB33, P242
[5]  
Aparicio A, 2000, HRC-J HIGH RES CHROM, V23, P324
[6]  
Bosque-Sendra JM, 1998, RRD PURE APPL ANALYT, V1, P115
[7]   Flow-through sensor for determination of butylated hydroxytoluene in cosmetics [J].
Capitán-Vallvey, LF ;
Valencia, MC ;
Nicolás, EA .
ANALYTICAL LETTERS, 2002, 35 (01) :65-81
[8]   Monoparameter sensors for the determination of the antioxidants butylated hydroxyanisole and n-propyl gallate in foods and cosmetics by flow injection spectrophotometry [J].
Capitán-Vallvey, LF ;
Valencia, MC ;
Nicolás, EA .
ANALYST, 2001, 126 (06) :897-902
[9]  
CAPITANVALLVEY LF, 1996, Patent No. 2079308
[10]  
*COSM TEWOR PRACT, 1978, CONS GEN COL OF FARM, P162