Monoparameter sensors for the determination of the antioxidants butylated hydroxyanisole and n-propyl gallate in foods and cosmetics by flow injection spectrophotometry

被引:30
作者
Capitán-Vallvey, LF [1 ]
Valencia, MC [1 ]
Nicolás, EA [1 ]
机构
[1] Univ Granada, Dept Analyt Chem, E-18071 Granada, Spain
关键词
D O I
10.1039/b101162f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-through optosensor with solid phase UV spectroscopic detection is proposed for the direct determination of single antioxidants, namely butylated hydroxyanisole (BHA) and n-propyl gallate (n-PG), without previous derivatization. The methods are based on the transient retention behaviour of these compounds in a flow-through cell packed with C-18 silica using ethanol-water mixtures as a carrier, and on the intrinsic absorbance monitored at 290 and 283 nm, respectively. After recording the analytical signal, the antioxidants were easily and quickly desorbed from the solid support by the same carrier. For BHA, calibration graphs were linear over the range 1.0-300.0 mg L-1 using area as the analytical parameter. The relative standard deviation (RSD) was between 0.5 and 1.6%. For n-PG, calibration graphs were linear over the range 1.0-300.0 mg L-1 in area and the RSD was between 1.4 and 1.5%. The methods were applied to the determination of these antioxidants in several food and cosmetics samples, and were validated using the standard additions method and an HPLC reference method.
引用
收藏
页码:897 / 902
页数:6
相关论文
共 23 条
[1]   ANALYTICAL APPLICATIONS OF CYLINDRICAL CARBON-FIBER MICROELECTRODES - SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF PHENOLIC ANTIOXIDANTS IN FOOD [J].
AGUI, ML ;
REVIEJO, AJ ;
YANEZSEDENO, P ;
PINGARRON, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2195-2200
[2]   Simultaneous kinetic determination of butylated hydroxyanisole and propyl gallate by coupling stopped-flow mixing technique and diode-array detection [J].
AguilarCaballos, MP ;
GomezHens, A ;
PerezBendito, D .
ANALYTICA CHIMICA ACTA, 1997, 354 (1-3) :173-179
[3]  
[Anonymous], 1988, ANALYST, V113, P1469
[4]  
[Anonymous], 1980, ANAL CHEM, V52, P2242
[5]  
[Anonymous], 1978, SPECTROCHIM ACTA, VB33, P242
[7]  
Bosque-Sendra JM, 1998, RRD PURE APPL ANALYT, V1, P115
[8]  
*BRIT STAND I, 1984, 684 BRIT STAND I, P4
[9]   Continuous-flow determination of natural and synthetic antioxidants in foods by gas chromatography [J].
González, M ;
Ballesteros, E ;
Gallego, M ;
Valcárcel, M .
ANALYTICA CHIMICA ACTA, 1998, 359 (1-2) :47-55
[10]   MICELLAR CATALYSIS IN KINETIC MULTICOMPONENT ANALYSIS - SIMULTANEOUS DETERMINATION OF BINARY-MIXTURES OF CYANIDE, SULFIDE, AND SULFITE IONS [J].
GONZALEZ, V ;
MORENO, B ;
SICILIA, D ;
RUBIO, S ;
PEREZBENDITO, D .
ANALYTICAL CHEMISTRY, 1993, 65 (14) :1897-1902