Impact of material properties of intervertebral disc on dynamic response of the human lumbar spine to vertical vibration: a finite element sensitivity study

被引:22
作者
Guo, Li-Xin [1 ]
Fan, Wei [1 ]
机构
[1] Northeastern Univ, Sch Mech Engn & Automat, 3-11 Wenhua Rd, Shenyang 110819, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
Lumbar spine; Finite element model; Vibration; Material sensitivity; Dynamic response; MODEL; COMPRESSION; VALIDATION; FREQUENCY; SEGMENT; LOADS;
D O I
10.1007/s11517-018-1873-5
中图分类号
TP39 [计算机的应用];
学科分类号
080201 [机械制造及其自动化];
摘要
This study aimed to determine the effect of variations in material properties of the intervertebral disc on dynamic response of the human lumbar spine to vertical vibration using a finite element model of the lumbar L1-S1 motion segment. The present material sensitivity study was conducted by varying elastic moduli for annulus ground substance (AGS), annulus fibers (AF), and nucleus pulposus (NP) in the disc. Transient dynamic analysis was performed initially on the model with basic material property under a sinusoidal vertical vibration load. Subsequently, the same analysis was done for each of the three disc components corresponding to high and low material property cases. The computed results were plotted as a function of time and compared. The AGS property displayed a larger impact on vertebral axial displacement and von Mises stress in AGS, and the AF property displayed a larger impact on disc bulge. In contrast, the NP property had little effect on all the response parameters. Additionally, the intradiscal pressure was found to be not sensitive to any of the disc properties. These findings may be helpful in adoption of appropriate material parameters for the intervertebral disc in finite element model of the lumbar spine used for vibration analysis.
引用
收藏
页码:221 / 229
页数:9
相关论文
共 35 条
[1]
Anderson Andrew E., 2007, Computer Methods in Biomechanics and Biomedical Engineering, V10, P171, DOI 10.1080/10255840601160484
[2]
An updated review of epidemiologic studies on the relationship between exposure to whole-body vibration and low back pain [J].
Bovenzi, M ;
Hulshof, CTJ .
JOURNAL OF SOUND AND VIBRATION, 1998, 215 (04) :595-611
[3]
Comparison of eight published static finite element models of the intact lumbar spine: Predictive power of models improves when combined together [J].
Dreischarf, M. ;
Zander, T. ;
Shirazi-Adl, A. ;
Puttlitz, C. M. ;
Adam, C. J. ;
Chen, C. S. ;
Goel, V. K. ;
Kiapour, A. ;
Kim, Y. H. ;
Labus, K. M. ;
Little, J. P. ;
Park, W. M. ;
Wang, Y. H. ;
Wilke, H. J. ;
Rohlmann, A. ;
Schmidt, H. .
JOURNAL OF BIOMECHANICS, 2014, 47 (08) :1757-1766
[4]
Patient-specific spine models. Part 1: finite element analysis of the lumbar intervertebral disc - a material sensitivity study [J].
Fagan, MJ ;
Julian, S ;
Siddall, DJ ;
Mohsen, AM .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H5) :299-314
[6]
INVESTIGATION OF VIBRATION CHARACTERISTICS OF THE LIGAMENTOUS LUMBAR SPINE USING THE FINITE-ELEMENT APPROACH [J].
GOEL, VK ;
PARK, H ;
KONG, WZ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (04) :377-383
[7]
Moment-rotation responses of the human lumbosacral spinal column [J].
Guan, Yabo ;
Yoganandan, Narayan ;
Moore, Jason ;
Pintar, Frank A. ;
Zhang, Jiangyue ;
Maiman, Dennis J. ;
Laud, Purushottam .
JOURNAL OF BIOMECHANICS, 2007, 40 (09) :1975-1980
[8]
Material Property Sensitivity Analysis on Resonant Frequency Characteristics of the Human Spine [J].
Guo, Li-Xin ;
Wang, Zhao-Wen ;
Zhang, Yi-Min ;
Lee, Kim-Kheng ;
Teo, Ee-Chon ;
Li, He ;
Wen, Bang-Chun .
JOURNAL OF APPLIED BIOMECHANICS, 2009, 25 (01) :64-72
[9]
Vibration characteristics of the human spine under axial cyclic loads: Effect of frequency and damping [J].
Guo, LX ;
Teo, EC ;
Lee, KK ;
Zhang, QH .
SPINE, 2005, 30 (06) :631-637
[10]
Sensitivity studies of pediatric material properties on juvenile lumbar spine responses using finite element analysis [J].
Jebaseelan, D. Davidson ;
Jebaraj, C. ;
Yoganandan, Narayan ;
Rajasekaran, S. ;
Kanna, Rishi M. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (05) :515-522