Image-guided endoscopic spine surgery - Part I. A feasibility study

被引:39
作者
Assaker, R
Cinquin, P
Cotten, A
Lejeune, JP
机构
[1] Univ Hosp, Dept Neurosurg, Lille, France
[2] Univ Hosp, Dept Radiol, Lille, France
[3] UFJ, Lab TIMC IMAG, CNRS, UMR 5525, La Tronche, France
关键词
image-guided surgery; computer-aided surgery; endoscopic spine surgery;
D O I
10.1097/00007632-200108010-00015
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A feasibility study was performed to determine the efficacy of computer assistance in endoscopic spine surgery. Objectives. To assess a new method for computer assistance based on image guidance during thoracoscopic or any endoscopic spine procedure. To evaluate the reproducibility, the sensitivity and the reliability of the technique first in vitro and second in clinical use. Summary of Background Data. The computer-based, image-guided surgery is now a routine tool used in open spine surgery. Exposure of the anatomy of the vertebra is needed for registration. This methodology is inapplicable in endoscopic approach. Fluoroscopic-based navigation combines the technology of image-guided surgery and C-arm fluoroscopy. The navigation is based on the fluoroscopic images acquired before surgery. This technology is applicable to endoscopic surgery but the navigation is based on fluoroscopic image. The computed tomography images are not exploited. There are no published data on a technique that allows image-guided surgery based on computed tomography and magnetic resonance imaging. Method. A laboratory study was performed on a thoracic human spine. One vertebra was marked on the right lateral side of the body with five titanium marks. A percutaneous reference frame was specifically designed to be placed in the pedicle of the same marked vertebrae. The reference frame acted as a 3D localizer and a registration tool. The spine model was scanned including the reference frame. A standard Stealth station treatment guidance platform (Medtronic, Sofamor Danek, Memphis, TN) was used for simulation. The registration was obtained using the reference frame. Twenty navigation procedure trials were done and the error was recorded based on the distance between the anatomical point and the corresponding virtual one. Results. Registration was always possible using the stealth station and a standard spine navigational software (spine 3, Medtronic Sofamor Danek, Memphis, TIN). The mean error after registration given by the computer was 0.96 mm. The mean error recorded during the navigation simulation was 1.6 mm. Conclusions. This technique allows the possibility of computed tomography and magnetic resonance imaging-based, image-guided endoscopic surgery. It is probable that in the near future, as image fusion technology improves, the fluoronavigation based on fluoroscopic images would enable to navigate on multimodal images. Otherwise the technique described in this article is the only reproducible one that allows computed tomography-based computer assistance during endoscopic procedures.
引用
收藏
页码:1705 / 1710
页数:6
相关论文
共 23 条
[1]
Image-guided anterior cervical corpectomy - A feasibility study [J].
Albert, TJ ;
Klein, GR ;
Vaccaro, AR .
SPINE, 1999, 24 (08) :826-830
[2]
Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures [J].
Bolger, C ;
Wigfield, C .
JOURNAL OF NEUROSURGERY, 2000, 92 (02) :175-180
[3]
EXTRACRANIAL APPLICATION OF THE FRAMELESS STEREOTAXIC OPERATING MICROSCOPE - EXPERIENCE WITH LUMBAR SPINE [J].
BRODWATER, BK ;
ROBERTS, DW ;
NAKAJIMA, T ;
FRIETS, EM ;
STROHBEHN, JW ;
KELLY, PJ ;
FRIEDMAN, WA .
NEUROSURGERY, 1993, 32 (02) :209-213
[4]
Design and evaluation of a system for microscope-assisted guided interventions (MAGI) [J].
Edwards, PJ ;
King, AP ;
Maurer, CR ;
de Cunha, DA ;
Hawkes, DJ ;
Hill, DLG ;
Gaston, RP ;
Fenlon, MR ;
Jusczyzck, A ;
Strong, AJ ;
Chandler, CL ;
Gleeson, MJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (11) :1082-1093
[5]
Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[6]
FOLEY K, 1998, J BONE JOINT SURG S3, V80, P245
[7]
Foley KT, 1996, NEUROSURG CLIN N AM, V7, P171
[8]
Computer-aided pedicle screw placement using frameless stereotaxis [J].
Glossop, ND ;
Hu, RW ;
Randle, JA .
SPINE, 1996, 21 (17) :2026-2034
[9]
Haberland N, 2000, Comput Aided Surg, V5, P18, DOI 10.1002/(SICI)1097-0150(2000)5:1<18::AID-IGS3>3.3.CO
[10]
2-K