Design and evaluation of a system for microscope-assisted guided interventions (MAGI)

被引:147
作者
Edwards, PJ [1 ]
King, AP
Maurer, CR
de Cunha, DA
Hawkes, DJ
Hill, DLG
Gaston, RP
Fenlon, MR
Jusczyzck, A
Strong, AJ
Chandler, CL
Gleeson, MJ
机构
[1] Guys Hosp, KCL, CISG, London SE1 9RT, England
[2] Guys Kings & St Thomas Dent Inst, Dept Prosthet Dent, London SE1 9RT, England
[3] Kings Coll Hosp London, London SE1 9RT, England
[4] Guys Hosp, ENT Surt, London SE1 9RT, England
基金
英国工程与自然科学研究理事会;
关键词
augmented reality; calibration; image-guided surgery; operating microscope; registration;
D O I
10.1109/42.896784
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The problem of providing surgical navigation using image overlays on the operative scene can be split into four main tasks-calibration of the optical system; registration of preoperative images to the patient; system and patient tracking, and display using a suitable visualization scheme. To achieve a convincing result in the magnified microscope view a very high alignment accuracy is required. We have simulated an entire image overlay system to establish the most significant sources of error and improved each of the stages involved. The microscope calibration process has been automated. We have introduced bone-implanted markers for registration and incorporated a locking acrylic dental stent (LADS) for patient tracking. The LADS can also provide a less-invasive registration device with mean target error of 0.7 mm in volunteer experiments. These improvements have significantly increased the alignment accuracy of our overlays. Phantom accuracy is 0.3-0.5 mm and clinical overlay errors were 0.5-1.0 mm on the bone fiducials and 0.5-4 mm on target structures. We have improved the graphical representation of the stereo overlays. The resulting system provides three-dimensional surgical navigation for microscope-assisted guided interventions (MAGI).
引用
收藏
页码:1082 / 1093
页数:12
相关论文
共 27 条
[1]  
Edwards P J, 1995, J Image Guid Surg, V1, P172, DOI 10.1002/(SICI)1522-712X(1995)1:3<172::AID-IGS7>3.0.CO
[2]  
2-7
[3]  
Edwards P J, 1998, Med Image Anal, V2, P355, DOI 10.1016/S1361-8415(98)80016-9
[4]  
EDWARDS PJ, 1995, P 6 BR MACH VIS C, V2, P691
[5]   Locking acrylic resin dental stent for image-guided surgery [J].
Fenlon, MR ;
Jusczyzck, AS ;
Edwards, PJ ;
King, AP .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (04) :482-485
[6]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[7]  
FLEIG OJ, 1998, COMP ASS RAD SURG TO
[8]   A FRAMELESS STEREOTAXIC OPERATING MICROSCOPE FOR NEUROSURGERY [J].
FRIETS, EM ;
STROHBEHN, JW ;
HATCH, JF ;
ROBERTS, DW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (06) :608-617
[9]  
Gonzalez R.C., 1992, DIGITAL IMAGE PROCES
[10]   A non-invasive patient registration and reference system for interactive intraoperative localization in intranasal sinus surgery [J].
Hauser, R ;
Westermann, B ;
Probst, R .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (04) :327-334