Enhanced characterization of complex proteomic samples using LC-MALDI MS/MS: Exclusion of redundant peptides from MS/MS analysis in replicate runs

被引:43
作者
Chen, HS
Rejtar, T
Andreev, V
Moskovets, E
Karger, BL
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem & Biol Chem, Boston, MA 02115 USA
关键词
D O I
10.1021/ac050956y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Due to the complexity of proteome samples, only a portion of peptides and thus proteins can be identified in a single LC-MS/MS analysis in current shotgun proteomics methodologies. It has been shown that replicate runs can be used to improve the comprehensiveness of the proteome analysis; however, high-intensity peptides tend to be analyzed repeatedly in different runs, thus reducing the chance of identifying low-intensity peptides. In contrast to commonly used online ESI-MS, offline MALDI decouples the separation from MS acquisition, thus allowing in-depth selection for specific precursor ions. Accordingly, we extended a strategy for offline LC-MALDI MS/MS analysis using a precursor ion exclusion list consisting of all identified peptides in preceding runs. The exclusion list eliminated redundant MS/MS acquisitions in subsequent runs, thus reducing MALDI sample depletion and allowing identification of a larger number of peptide identifications in the cumulative dataset. In the analysis of the digest of an Escherichia coli lysate, the exclusion list strategy resulted in a 25% increase in the number of unique peptide identifications in the second run, in contrast to simply pooling MS/MS data from two replicate runs. To reduce the increased LC analysis time for repeat runs, a four-column multiplexed LC system was developed to carry out separation simultaneously. The multiplexed LC-MALDI MS provides a high-throughput platform to utilize the exclusion list strategy in proteome analysis.
引用
收藏
页码:7816 / 7825
页数:10
相关论文
共 31 条
[1]  
ANDREEV V, 2004, P 52 ASMS C MASS SPE
[2]   A universal denoising and peak picking algorithm for LC-MS based on matched filtration in the chromatographic time domain [J].
Andreev, VP ;
Rejtar, T ;
Chen, HS ;
Moskovets, EV ;
Ivanov, AR ;
Karger, BL .
ANALYTICAL CHEMISTRY, 2003, 75 (22) :6314-6326
[3]   High-speed, high-resolution monolithic capillary LC-MALDI MS using an off-line continuous deposition interface for proteomic analysis [J].
Chen, HS ;
Rejtar, T ;
Andreev, V ;
Moskovets, E ;
Karger, BL .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2323-2331
[4]   Device for the reversed-phase separation and on-target deposition of peptides incorporating a hydrophobic sample barrier for matrix-assisted laser desorption/ionization mass spectrometry [J].
Chen, VC ;
Cheng, K ;
Ens, W ;
Standing, KG ;
Nagy, JI ;
Perreault, H .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :1189-1196
[5]   A new method to analyze matrix-assisted laser desorption/ionization time-of-flight peptide profiling mass spectra [J].
Dekker, LJ ;
Dalebout, JC ;
Siccama, I ;
Jenster, G ;
Smitt, PAS ;
Luider, TM .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (07) :865-870
[6]   An automated noncontact deposition interface for liquid chromatography matrix-assisted laser desorption/ionization mass spectrometry [J].
Ericson, C ;
Phung, QT ;
Horn, DM ;
Peters, EC ;
Fitchett, JR ;
Ficarro, SB ;
Salomon, AR ;
Brill, LM ;
Brock, A .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2309-2315
[7]  
Hui JPM, 2003, P 51 ASMS C MASS SPE
[8]   Development of a multiplexed microcapillary liquid chromatography system for high-throughput proteome analysis [J].
Lee, H ;
Griffin, TJ ;
Gygi, SP ;
Rist, B ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 2002, 74 (17) :4353-4360
[9]   Direct analysis of protein complexes using mass spectrometry [J].
Link, AJ ;
Eng, J ;
Schieltz, DM ;
Carmack, E ;
Mize, GJ ;
Morris, DR ;
Garvik, BM ;
Yates, JR .
NATURE BIOTECHNOLOGY, 1999, 17 (07) :676-682
[10]   Global analysis of the Deinococcus radiodurans proteome by using accurate mass tags [J].
Lipton, MS ;
Pasa-Tolic, L ;
Anderson, GA ;
Anderson, DJ ;
Auberry, DL ;
Battista, KR ;
Daly, MJ ;
Fredrickson, J ;
Hixson, KK ;
Kostandarithes, H ;
Masselon, C ;
Markillie, LM ;
Moore, RJ ;
Romine, MF ;
Shen, YF ;
Stritmatter, E ;
Tolic, N ;
Udseth, HR ;
Venkateswaran, A ;
Wong, LK ;
Zhao, R ;
Smith, RD .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (17) :11049-11054