Biomechanical study of a novel self-locking plate system for anterior cervical fixation

被引:8
作者
Lao, Lifeng [1 ]
Li, Qianyi [1 ]
Zhong, Guibin [1 ]
Song, Chao [1 ]
Li, Yuanchao [2 ]
Xu, Mingze [1 ]
Liu, Zude [1 ]
机构
[1] Shanghai Jiao Tong Univ, Ren Ji Hosp, Sch Med, Dept Orthopaed Surg, Shanghai 200030, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai 200030, Peoples R China
关键词
Cervical fixation; Self-locking plate; Biomechanics; DePuy plate; BONE-MINERAL DENSITY; CADAVERIC MODEL; SCREW TORQUE; SPINE; STABILIZATION; FUSION;
D O I
10.1186/s13018-014-0120-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Anterior cervical plate had developed continuously, and this study aimed to assess the biomechanics of a novel self-locking plate system for anterior cervical fixation designed by ourselves. Methods: Twelve anterior cervical plates (i.e., six novel plates and six DePuy plates) were subjected to a pull-out test and a fatigue test. In addition, 12 C1-T1 cervical spine specimens underwent anterior cervical corpectomy and C5 fusion using six novel plates and six DePuy plates. Pre- and postoperative range of motion, load-displacement, axial stiffness, torque, and twisting stiffness were compared. Results: No differences in maximum pull-out force, relative displacement, or energy absorption were observed between the DePuy plates and the novel plates (P > 0.05). The novel plate system could bear an average of 5.6 x 10(5) times of loading, while the DePuy plate could bear 5.4 x 10(5) times of loading. The fatigue strengths of the new plate system and the DePuy plate were 490.75 and 485.86 MPa, respectively. No differences in fatigue life or strength were observed between the two types of plates. Cervical spine stability increased significantly after internal fixation. No differences in range of motion, load-displacement, axial stiffness, torque, or twisting stiffness were observed between the novel self-locking plate and the DePuy plate (P > 0.05). Conclusions: Compared to the DePuy plate, the novel anterior cervical self-locking plate system described here has good strength and fastening ability, allowing it to provide sufficient biomechanical stability. Further clinical assessment of this system is needed.
引用
收藏
页数:7
相关论文
共 22 条
[1]
STABILIZATION OF THE CERVICAL SPINE BY ANTERIOR FUSION [J].
BAILEY, RW ;
BADGLEY, CE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1960, 42 (04) :565-594
[2]
Black J, 1988, ORTHOPAEDIC BIOMATER, P72
[3]
BOHLER J, 1980, J TRAUMA, V20, P203
[4]
Biomechanical evaluation of Caspar and Cervical Spine Locking Plate systems in a cadaveric model [J].
Clausen, JD ;
Ryken, TC ;
Traynelis, VC ;
Sawin, PD ;
Dexter, F ;
Goel, VK .
JOURNAL OF NEUROSURGERY, 1996, 84 (06) :1039-1045
[5]
Adverse Events Associated With Anterior Cervical Spine Surgery [J].
Daniels, Alan H. ;
Riew, K. Daniel ;
Yoo, J. U. ;
Ching, Alexander ;
Birchard, Keith R. ;
Kranenburg, Andy J. ;
Hart, Robert A. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 (12) :729-738
[6]
Deodhar AA, 1996, BRIT J RHEUMATOL, V35, P309
[7]
BIOMECHANICAL TESTING OF THE SPINE - LOAD-CONTROLLED VERSUS DISPLACEMENT-CONTROLLED ANALYSIS - DISCUSSION [J].
GOEL, VK ;
WILDER, DG ;
POPE, MH ;
EDWARDS, WT .
SPINE, 1995, 20 (21) :2354-2357
[8]
Biomechanical evaluation of anterior cervical spine stabilization [J].
Grubb, MR ;
Currier, BL ;
Shih, JS ;
Bonin, V ;
Grabowski, JJ ;
Chao, EYS .
SPINE, 1998, 23 (08) :886-892
[9]
Hall M. J., 2010, NATL HLTH STAT REPOR, V29, P24
[10]
Hall MJ., 2010, NATL HOSP DISCHARGE, DOI DOI 10.3886/ICPSR28162.V1