Airborne intercomparison of vacuum ultraviolet fluorescence and tunable diode laser absorption measurements of tropospheric carbon monoxide

被引:120
作者
Holloway, JS
Jakoubek, RO
Parrish, DD
Gerbig, C
Volz-Thomas, A
Schmitgen, S
Fried, A
Wert, B
Henry, B
Drummond, JR
机构
[1] NOAA, Aeron Lab, Boulder, CO 80303 USA
[2] Univ Colorado, Cooperat Inst Res Environm Sci, Boulder, CO 80309 USA
[3] Forschungszentrum Julich, Inst Chem & Dynam Geosphare, D-52425 Julich, Germany
[4] Natl Ctr Atmospher Res, Boulder, CO 80307 USA
[5] Univ Toronto, Dept Phys, Toronto, ON M5 51A7, Canada
关键词
D O I
10.1029/2000JD900237
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
During the fall 1997 North Atlantic Regional Experiment (NARE 97), two separate intercomparisons of aircraft-based carbon monoxide measurement instrumentation were conducted. On September 2, CO measurements were simultaneously made aboard the National Oceanic and Atmospheric Administration (NOAA) WP-3 by vacuum ultraviolet (VUV) fluorescence and by tunable diode laser absorption spectroscopy (TDLAS), On September 18, an intercomparison flight was conducted between two separate instruments, both employing the VUV fluorescence method, on the NOAA WP-3 and the U,K. Meteorological Office C-130 Hercules. The results indicate that both of the VUV fluorescence instruments and the TDLAS system are capable of measuring ambient CO accurately and precisely with no apparent interferences in 5 s. The accuracy of the measurements, based upon three independent calibration systems, is indicated by the agreement to within 11% with systematic offsets of less than 1 ppbv. In addition, one of the groups participated in the Measurement of Air Pollution From Satellite (MAPS) intercomparison [Novelli ef at., 1998] with a different measurement technique but very similar calibration system, and agreed with the accepted analysis to within 5%. The precision of the measurements is indicated by the variability of the ratio of simultaneous measurements from the separate instruments, This variability is consistent with the estimated precisions of 1.5 ppbv and 2.2 ppbv for the 5 s average results of the C-130 and the WP-3 instruments, respectively, and indicates a precision of approximately 3.6% for the TDLAS instrument. The excellent agreement of the instruments in both intercomparisons demonstrates that significant interferences in the measurements are absent in air masses that ranged from 7 km in the midtroposphere to boundary layer conditions including subtropical marine air and continental outflow with embedded urban plumes. The intercomparison of the two VUV instruments that differed widely in their design indicates that the VUV fluorescence technique for CO measurements is not particularly sensitive to the details of its implementation. These intercomparisons help to establish the reliability of ambient CO measurements by the VUV fluorescence technique.
引用
收藏
页码:24251 / 24261
页数:11
相关论文
共 31 条
  • [1] INSTRUMENTAL REQUIREMENTS FOR GLOBAL ATMOSPHERIC CHEMISTRY
    ALBRITTON, DL
    FEHSENFELD, FC
    TUCK, AF
    [J]. SCIENCE, 1990, 250 (4977) : 75 - 81
  • [2] [Anonymous], 1986, ENV POL SUS DEV
  • [3] Dickerson R. R., 1988, Journal of Atmospheric and Oceanic Technology, V5, P424, DOI 10.1175/1520-0426(1988)005<0424:MOACGF>2.0.CO
  • [4] 2
  • [5] FINK E, 1976, THESIS U BONN GERMAN
  • [6] CORRELATIVE NATURE OF OZONE AND CARBON-MONOXIDE IN THE TROPOSPHERE - IMPLICATIONS FOR THE TROPOSPHERIC OZONE BUDGET
    FISHMAN, J
    SEILER, W
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 1983, 88 (NC6) : 3662 - 3670
  • [7] INTERCOMPARISON OF TUNABLE DIODE-LASER AND GAS FILTER CORRELATION-MEASUREMENTS OF AMBIENT CARBON-MONOXIDE
    FRIED, A
    HENRY, B
    PARRISH, DD
    CARPENTER, JR
    BUHR, MP
    [J]. ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1991, 25 (10): : 2277 - 2284
  • [8] Airborne tunable diode laser measurements of trace atmospheric gases
    Fried, A
    Wert, BP
    Henry, B
    Drummond, JR
    [J]. FABRICATION, TESTING, AND RELIABILITY OF SEMICONDUCTOR LASERS III, 1998, 3285 : 154 - 162
  • [9] Airborne tunable diode laser measurements of formaldehyde
    Fried, A
    Wert, BP
    Henry, B
    Drummond, JR
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1999, 55 (10) : 2097 - 2110
  • [10] Laboratory, ground-based, and airborne tunable diode laser systems: performance characteristics and applications in atmospheric studies
    Fried, A
    Henry, B
    Wert, B
    Sewell, S
    Drummond, JR
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 67 (03): : 317 - 330