On-chip protein sample desalting and preparation for direct coupling with electrospray ionization mass spectrometry

被引:70
作者
Lion, N [1 ]
Gellon, JO [1 ]
Jensen, H [1 ]
Girault, HH [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Chim Mol & Biol, Lab Electrochim Phys & Analyt, CH-1015 Lausanne, Switzerland
关键词
chip technology; membranes; desalting methods; proteins; poly(vinylidene difluoride); iodoacetamide; lactoglobulin;
D O I
10.1016/S0021-9673(03)00771-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A membrane-based desalting step integrated in a MS microchip is presented: drugs, peptides and proteins are adsorbed on a hydrophobic poly(vinylidene difluoride) membrane, which allows the washing out of salts. The integration with microfluidics permits a controlled elution of analytes from the membrane and their direct mass spectrometric analysis by electrospray ionisation MS. The desalting process is demonstrated with picomole amounts of propanolol, insulin and cytochrome c. Moreover, this stop-and-go desalting process is tolerant to high concentrations of urea, and to the presence of reductants such as dithiothreitol. This particular feature allowed the chemical tagging of cysteines in beta-lactoglobulin A with iodoacetamide. Finally, the integration of chemical tagging, on-chip desalting and MS microchip paves the way for the development of high-throughput analytical procedure for structural proteomics. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 57 条
[1]   The methanol-induced conformational transitions of β-lactoglobulin, cytochrome c, and ubiquitin at low pH:: A study by electrospray ionization mass spectrometry [J].
Babu, KR ;
Moradian, A ;
Douglas, DJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (03) :317-328
[2]   Methanol-induced conformations of myoglobin at pH 4.0 [J].
Babu, KR ;
Douglas, DJ .
BIOCHEMISTRY, 2000, 39 (47) :14702-14710
[3]   Effects of salt concentration on analyte response using electrospray ionization mass spectrometry [J].
Constantopoulos, TL ;
Jackson, GS ;
Enke, CG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (07) :625-634
[4]   Free energy for blue copper protein unfolding determined by electrospray ionisation mass spectrometry [J].
Cunsolo, V ;
Foti, S ;
La Rosa, C ;
Saletti, R ;
Canters, GW ;
Verbeet, MP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (19) :1817-1825
[5]   Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine [J].
Deng, YZ ;
Henion, J ;
Li, JJ ;
Thibault, P ;
Wang, C ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :639-646
[6]   Chip-based quantitative capillary electrophoresis/mass spectrometry determination of drugs in human plasma [J].
Deng, YZ ;
Zhang, NW ;
Henion, J .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1432-1439
[7]   Direct monitoring of protein-chemical reactions utilising nanoelectrospray mass spectrometry [J].
Fligge, TA ;
Kast, J ;
Bruns, K ;
Przybylski, M .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (02) :112-118
[8]  
Galvani M, 2001, ELECTROPHORESIS, V22, P2058, DOI 10.1002/1522-2683(200106)22:10<2058::AID-ELPS2058>3.0.CO
[9]  
2-Z
[10]   A quantitative, high-throughput screen for protein stability [J].
Ghaemmaghami, S ;
Fitzgerald, MC ;
Oas, TG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (15) :8296-8301