Three-dimensional visualization of coronary arteries in excised hearts

被引:2
作者
Zotz, RJ
Zirlik, A
Raeder, T
Hahn, M
Binner, C
Ullmann, C
Grimm, M
Schuler, G
机构
[1] Univ Leipzig, Ctr Heart, Dept Internal Med Cardiol, D-04289 Leipzig, Germany
[2] Univ Leipzig, Ctr Heart, Dept Cardiothorac Surg, D-04289 Leipzig, Germany
[3] Fraunhofer Inst Cognit Comp & Med Imaging, Darmstadt, Germany
关键词
D O I
10.1067/mje.2001.110781
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We sought to image coronary arteries in excised hearts. Methods: Twelve excised pigs' hearts were imaged in a water bath. The aortic valve was closed surgically. A contrast agent (Echovist) was Injected into the aortic root and selectively into single coronary arteries. Three-dimensional (3D) imaging was performed with TomTec Echoscan equipment. Mechanical rotations were performed at 1 degrees intervals. The hearts were visualized by InVivo software. Selective coloring of coronary arteries in 3D data sets was obtained by using color superpositioning, which differentiates information before and after injection of contrast. Distance measurements were performed in conventional 3D echocardiograms of coronary arteries and color-superimposed echocardiograms and compared with those from angiograms and casts. Results: After a learning curve, during which optimal conditions for the visualization of coronary arteries were determined, a quick display of all major parts of the coronary tree was obtained. Distance measurements (n >400) revealed that fundamental contrast echocardiography overestimated angiography by 25% +/- 5% and casts by 28% +/- 6%. However, distances in color-superimposed echocardiograms (flow mode 4) were not significantly different from those obtained from angiograms and casts. In harmonic contrast echocardiograms, color super-positioning gave smaller distances compared with those from fundamental contrast echocardiograms, though they were still significantly larger than the reference diameters. Conclusions: The 3D Imaging of epicardial coronary arteries under ideal conditions in a water bath seems feasible and provides insight into coronary visualization with the use of ultrasonography.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 14 条
[1]   Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1964-1971
[2]   Visualization of the coronary arteries in three-dimensional reconstructions using respiratory gated magnetic resonance imaging [J].
Achenbach, S ;
Kessler, W ;
Moshage, WE ;
Ropers, D ;
Zink, D ;
Kroeker, R ;
Nitz, W ;
Laub, G ;
Bachmann, K .
CORONARY ARTERY DISEASE, 1997, 8 (07) :441-448
[3]   New noninvasive method for coronary flow reserve assessment - Contrast-enhanced transthoracic second harmonic echo Doppler [J].
Caiati, C ;
Montaldo, C ;
Zedda, N ;
Bina, A ;
Iliceto, S .
CIRCULATION, 1999, 99 (06) :771-778
[4]   Visualization and functional assessment of proximal and middle left anterior descending coronary stenoses in humans with magnetic resonance imaging [J].
Hundley, WG ;
Hamilton, CA ;
Clarke, GD ;
Hillis, LD ;
Herrington, DM ;
Lange, RA ;
Applegate, RJ ;
Thomas, MS ;
Payne, J ;
Link, KM ;
Peshock, RM .
CIRCULATION, 1999, 99 (25) :3248-3254
[5]   TRANSESOPHAGEAL DOPPLER ECHOCARDIOGRAPHY EVALUATION OF CORONARY BLOOD-FLOW VELOCITY IN BASE-LINE CONDITIONS AND DURING DIPYRIDAMOLE-INDUCED CORONARY VASODILATION [J].
ILICETO, S ;
MARANGELLI, V ;
MEMMOLA, C ;
RIZZON, P .
CIRCULATION, 1991, 83 (01) :61-69
[6]   Visualization and quantification of myocardial mass at risk using three-dimensional contrast echocardiography [J].
Kasprzak, JD ;
Vletter, WB ;
Roelandt, JRTC ;
van Meegen, JR ;
Johnson, R ;
Ten Cate, FJ .
CARDIOVASCULAR RESEARCH, 1998, 40 (02) :314-321
[7]   Second harmonic imaging of an intravenously administered echocardiographic contrast agent - Visualization of coronary arteries and measurement of coronary blood flow [J].
Mulvagh, SL ;
Foley, DA ;
Aeschbacher, BC ;
Klarich, KK ;
Seward, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (06) :1519-1525
[8]   PREPROCESSING AND VOLUME RENDERING OF 3D ULTRASONIC DATA [J].
SAKAS, G ;
SCHREYER, LA ;
GRIMM, M .
IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1995, 15 (04) :47-54
[9]  
SAKAS G, 1996, P SIGGRAPH 95, P465
[10]   DOES VISUAL INTERPRETATION OF THE CORONARY ARTERIOGRAM PREDICT THE PHYSIOLOGIC IMPORTANCE OF A CORONARY STENOSIS [J].
WHITE, CW ;
WRIGHT, CB ;
DOTY, DB ;
HIRATZA, LF ;
EASTHAM, CL ;
HARRISON, DG ;
MARCUS, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 310 (13) :819-824