Photopolymerized sol-gel frits for packed columns in capillary electrochromatography

被引:53
作者
Kato, M [1 ]
Dulay, MT [1 ]
Bennett, BD [1 ]
Quirino, JP [1 ]
Zare, RN [1 ]
机构
[1] Stanford Univ, Dept Chem, Stanford, CA 94305 USA
关键词
sol-gel; electrochromatography; enantiomer separation; amino acids;
D O I
10.1016/S0021-9673(01)00772-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Porous sol-gel frits are fabricated in a capillary column by filling it with a solution of 3-(trimethoxysilyl)propyl methacrylate, hydrochloric acid, water, toluene (porogen), and a photoinitiator (Irgacure 1800) and exposing it to UV light at 365 nm for 5 min. The separation column (30 cmx75 mum I.D.) contains between the inlet and outlet frits a 15-cm packed segment filled with 5-mum silica particles modified with the chiral compound (S)-N-3,5-dinitrobenzoyl-1-naphthylglycine. A detection window (I mm long) is placed immediately after the outlet frit. To demonstrate the performance of this chiral separation column, mixtures of 16 different amino acids (three of which are not naturally occurring) derivatized with the fluorogenic reagent 4-fluoro-7-nitro-2,1,3-benzoxadiazole were separated by capillary chromatography. The enantiomeric separation of the column results in a resolution ranging from 1.21 to 8.29, and a plate height ranging from 8.7 to 39 mum. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 36 条
[1]   Analysis of acidic compounds using capillary electrochromatography [J].
Altria, KD ;
Smith, NW ;
Turnbull, CH .
JOURNAL OF CHROMATOGRAPHY B, 1998, 717 (1-2) :341-353
[2]   Sintered octadecylsilica as monolithic column packing in capillary electrochromatography and micro high-performance liquid chromatography [J].
Asiaie, R ;
Huang, X ;
Farnan, D ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1998, 806 (02) :251-263
[3]   EVALUATION OF THE PARAMETERS DETERMINING THE PERFORMANCE OF ELECTROCHROMATOGRAPHY IN PACKED CAPILLARY COLUMNS [J].
BEHNKE, B ;
GROM, E ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :207-213
[4]   CAPILLARY ELECTROCHROMATOGRAPHY - SOME IMPORTANT CONSIDERATIONS IN THE PREPARATION OF PACKED CAPILLARIES AND THE CHOICE OF MOBILE-PHASE BUFFERS [J].
BOUGHTFLOWER, RJ ;
UNDERWOOD, T ;
PATERSON, CJ .
CHROMATOGRAPHIA, 1995, 40 (5-6) :329-335
[5]  
Carney RA, 1999, HRC-J HIGH RES CHROM, V22, P29
[6]   Enantioseparations in capillary electromigration techniques: recent developments and future trends [J].
Chankvetadze, B ;
Blaschke, G .
JOURNAL OF CHROMATOGRAPHY A, 2001, 906 (1-2) :309-363
[7]   Macroporous photopolymer frits for capillary electrochromatography [J].
Chen, JR ;
Dulay, MT ;
Zare, RN ;
Svec, F ;
Peters, E .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1224-1227
[8]  
Chirica G, 1999, ELECTROPHORESIS, V20, P50, DOI 10.1002/(SICI)1522-2683(19990101)20:1<50::AID-ELPS50>3.0.CO
[9]  
2-O
[10]  
Cikalo MG, 1998, ANALYST, V123, p87R