Validation of Monte Carlo calculated surface doses for megavoltage photon beams

被引:55
作者
Abdel-Rahman, W [1 ]
Seuntjens, JP [1 ]
Verhaegen, F [1 ]
Deblois, F [1 ]
Podgorsak, EB [1 ]
机构
[1] McGill Univ, Ctr Hlth, Dept Med Phys, Montreal, PQ H3G 1A4, Canada
关键词
surface dose; extrapolation chamber; megavoltage photon beams; build-up region; Monte-Carlo calculations;
D O I
10.1118/1.1829401
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent work has shown that there is significant uncertainty in measuring build-up doses in megavoltage photon beams especially at high energies. In this present investigation we used a phantom-embedded extrapolation chamber (PEEC) made of Solid Water(TM) to validate Monte Carlo (MC)calculated doses in the dose build-up region for 6 and 18 MV x-ray beams. The study showed that the percentage depth ionizations (PDIs) obtained from measurements are higher than the percentage depth doses (PDDs) obtained with Monte Carlo techniques. To validate the MC-calculated PDDs, the design of the PEEC was incorporated into the simulations. While the MC-calculated and measured PDIs in the dose build-up region agree with one another for the 6 MV beam, a non-negligible difference is observed for the 18 MV x-ray beam. A number of experiments and theoretical studies of various possible effects that could be the source of this discrepancy were performed. The contribution of contaminating neutrons and protons to the build-up dose region in the 18 MV x-ray beam is negligible. Moreover, the MC calculations using the XCOM photon cross-section database and the NIST bremsstrahlung differential cross section do not explain the discrepancy between the MC calculations and measurement in the dose build-up region for the 18 MV. A simple incorporation of triplet production events into the MC dose calculation increases the calculated doses in the build-up region but does not fully account for the discrepancy between measurement and calculations for the 18 MV x-ray beam. (C) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:286 / 298
页数:13
相关论文
共 28 条
[1]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[2]   STOPPING-POWER RATIO FOR A PHOTON SPECTRUM AS A WEIGHTED SUM OF THE VALUES FOR MONOENERGETIC PHOTON BEAMS [J].
ANDREO, P ;
NAHUM, AE .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (10) :1055-1065
[3]  
Andreo P, 2000, TECHNICAL REPORT SER, V398
[4]  
Berger M.J., 1998, NIST STANDARD REFERE
[5]   R(50) as a beam quality specifier for selecting stopping-power ratios and reference depths for electron dosimetry [J].
Burns, DT ;
Ding, GX ;
Rogers, DWO .
MEDICAL PHYSICS, 1996, 23 (03) :383-388
[6]   CALCULATION OF STOPPING POWER RATIOS USING REALISTIC CLINICAL ELECTRON-BEAMS [J].
DING, GX ;
ROGERS, DWO ;
MACKIE, TR .
MEDICAL PHYSICS, 1995, 22 (05) :489-501
[7]   Dose discrepancies between Monte Carlo calculations and measurements in the buildup region for a high-energy photon beam [J].
Ding, GX .
MEDICAL PHYSICS, 2002, 29 (11) :2459-2463
[8]   Are neutrons responsible for the dose discrepancies between Monte Carlo calculations and measurements in the build-up region for a high-energy photon beam? [J].
Ding, GX ;
Duzenli, C ;
Kalach, NI .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (17) :3251-3261
[9]   MEASUREMENT OF DOSE IN THE BUILDUP REGION USING FIXED-SEPARATION PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1990, 17 (01) :17-26
[10]  
IAEA, 2000, HDB PHOT DAT APPL CR