Evaluation of operational parameters affecting semiquantitative multi-elemental analysis by inductively coupled plasma mass spectrometry

被引:31
作者
Soldevila, J [1 ]
El Himri, M [1 ]
Pastor, A [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Valencia, Spain
关键词
inductively coupled plasma mass spectrometry; multi-elemental semiquantitative analysis;
D O I
10.1039/a802050g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A systematic study was carried out on the effect of ICP-MS operational parameters, such as dwell time, sweeps per reading, readings per replicate and number of replicates, on the precision and accuracy of results obtained in the semiquantitative mode by using Rh as internal standard and Ge, In and Ri for internal calibration of the instrument. In order to improve the quantitative analysis of major elements, such as Na, Mg, K and Ca, the detector attenuation (OmniRange parameter) must be recalibrated by using a multi-standard solution of these elements, Under these conditions, accurate results were obtained with a total measurement time of 103 s per sample, covering the whole mass range from 6 to 238 mu. The applicability of the methodology developed was confirmed by the analysis of a drinking water certified reference material.
引用
收藏
页码:803 / 807
页数:5
相关论文
共 19 条
[1]   SEMIQUANTITATIVE ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
AMARASIRIWARDENA, CJ ;
GERCKEN, B ;
ARGENTINE, MD ;
BARNES, RM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (06) :457-462
[2]   Semiquantitative analysis of biological materials by inductively coupled plasma-mass spectrometry [J].
Amarasiriwardena, D ;
Durrant, SF ;
Lasztity, A ;
Krushevska, A ;
Argentine, MD ;
Barnes, RM .
MICROCHEMICAL JOURNAL, 1997, 56 (03) :352-372
[3]   COMPARATIVE-STUDY ON THE TRACE AND RARE-EARTH ELEMENT ANALYSIS OF AN INDIAN POLYMETALLIC NODULE REFERENCE SAMPLE BY INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
BALARAM, V ;
ANJAIAH, KV ;
REDDY, MRP .
ANALYST, 1995, 120 (05) :1401-1406
[4]   EARLY EXPERIENCES WITH INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) :553-555
[5]  
BECH GL, 1988, J ANAL ATOM SPECTROM, V3, P771
[6]   DIRECT ATOMIC SPECTROMETRIC ANALYSIS BY SLURRY ATOMIZATION .7. ANALYSIS OF COAL USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
EBDON, L ;
FOULKES, ME ;
PARRY, HGM ;
TYE, CT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :753-761
[7]   SEMIQUANTITATIVE SURVEY CAPABILITIES OF INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
EKIMOFF, D ;
VANNORSTRAND, AM ;
MOWERS, DA .
APPLIED SPECTROSCOPY, 1989, 43 (07) :1252-1257
[9]   MASS-SPECTROMETRY OF INDUCTIVELY COUPLED PLASMAS [J].
HOUK, RS .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :A97-&
[10]  
JARVIS KE, 1992, HDB INDUCTIVELY COUP, P194