Perfusion imaging using FOCI RF pulses

被引:34
作者
Yongbi, MN
Branch, CA
Helpern, JA
机构
[1] Nathan S Kline Inst Psychiat Res, Ctr Adv Brain Imaging, Orangeburg, NY 10962 USA
[2] Albert Einstein Coll Med, Dept Radiol & Neurosci, New York, NY USA
[3] NYU, Sch Med, Dept Psychiat & Radiol, New York, NY USA
关键词
FAIR; FOCI; hyperbolic secant; perfusion; slice profile;
D O I
10.1002/mrm.1910400622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Pulsed arterial spin-tagging techniques for perfusion measurements (e.g., echo planar MR imaging and signal targeting with alternating radiofrequency (EPISTAR), flow-sensitive alternating inversion recovery (FAIR), quantitative imaging of perfusion using a single subtraction (QUIPPS), uninverted FAIR (UNFAIR)) generally use hyperbolic secant (HS) pulses for spin inversion, The performance of these techniques depends on the inversion efficiency, as well as the sharpness of the slice profiles. Frequency offset corrected inversion (FOCI) pulses, a recently proposed HS variant, can provide slice profiles with edges that can be up to 10 times sharper than those obtained with conventional HS pulses, In this communication, the implementation and application of the C-shape FOCI pulse for perfusion imaging in rat brain with the FAIR technique is summarized. Despite providing a more rectangular slice profile than a conventional HS pulse, it is demonstrated both theoretically and experimentally that the FAIR perfusion signal is not increased by using a FOCI tagging pulse, However, the use of a FOCI inversion pulse is shown to significantly minimize static signal subtraction errors that are common with conventional HS pulses. Finally, the suitability of the pulse for perfusion studies is demonstrated, in vivo, on rat brain.
引用
收藏
页码:938 / 943
页数:6
相关论文
共 19 条
[1]  
Calamante F, 1996, NMR BIOMED, V9, P79, DOI 10.1002/(SICI)1099-1492(199604)9:2<79::AID-NBM399>3.0.CO
[2]  
2-4
[3]   QUALITATIVE MAPPING OF CEREBRAL BLOOD-FLOW AND FUNCTIONAL LOCALIZATION WITH ECHO-PLANAR MR-IMAGING AND SIGNAL TARGETING WITH ALTERNATING RADIO-FREQUENCY [J].
EDELMAN, RR ;
SIEWERT, B ;
DARBY, DG ;
THANGARAJ, V ;
NOBRE, AC ;
MESULAM, MM ;
WARACH, S .
RADIOLOGY, 1994, 192 (02) :513-520
[4]   Slice profile effects in adiabatic inversion: Application to multislice perfusion imaging [J].
Frank, LR ;
Wong, EC ;
Buxton, RB .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :558-564
[5]  
HELPERN JA, 1997, MAGN RESON IMAGING, V31, P454
[6]   Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional brain imaging [J].
Kim, SG ;
Tsekos, NV .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) :425-435
[7]   QUANTIFICATION OF RELATIVE CEREBRAL BLOOD-FLOW CHANGE BY FLOW-SENSITIVE ALTERNATING INVERSION-RECOVERY (FAIR) TECHNIQUE - APPLICATION TO FUNCTIONAL MAPPING [J].
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :293-301
[8]   MR PERFUSION STUDIES WITH T-1-WEIGHTED ECHO-PLANAR IMAGING [J].
KWONG, KK ;
CHESLER, DA ;
WEISSKOFF, RM ;
DONAHUE, KM ;
DAVIS, TL ;
OSTERGAARD, L ;
CAMPBELL, TA ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :878-887
[9]   Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy [J].
Ordidge, RJ ;
Wylezinska, M ;
Hugg, JW ;
Butterworth, E ;
Franconi, F .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :562-566
[10]   IMAGE-SELECTED INVIVO SPECTROSCOPY (ISIS) - A NEW TECHNIQUE FOR SPATIALLY SELECTIVE NMR-SPECTROSCOPY [J].
ORDIDGE, RJ ;
CONNELLY, A ;
LOHMAN, JAB .
JOURNAL OF MAGNETIC RESONANCE, 1986, 66 (02) :283-294