Validity and stability of a computerized metabolic system with mixing chamber

被引:97
作者
Foss, O [1 ]
Hallén, J [1 ]
机构
[1] Norwegian Univ Sport & Phys Educ, Inst Sport & Biol Studies, N-0806 Oslo, Norway
关键词
Oxycon Pro; Douglas bag method; reproducibility; drift;
D O I
10.1055/s-2004-821317
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aim of this study was to validate a computerized metabolic system with mixing chamber (Oxycon Pro, Erich Jaeger GrnbH, Hoechberg, Germany) against the Douglas bag method (1) over a large range of ventilations and (2) for drift during shorter (25min time trial) and longer (similar to three months) test periods. Eighteen well-trained/elite cyclists performed graded exercise tests, maximal oxygen uptake tests and time trial tests on an electromagnetic braked cycle ergometer. Respiratory variables were measured simultaneously, once or several times in every test by the Oxycon Pro and the Douglas bag method. (1) Overall, oxygen uptake was 0.8 % (0.031 (.) min(-1)) lower with the Oxycon Pro than with the Douglas bag method with a coefficient of variation of 1.2% (n = 802) (p < 0.05). (2) During the time trials, oxygen uptake measured with the Oxycon Pro gradually decreased from 0.5% (0.021) lower than the Douglas bag method at 5 min to 1.0% (0.051) lower at 25min (p < 0.05). Over the period of three months of testing, oxygen uptake measured with the Oxycon Pro gradually increased from 1.1% (0.041) lower than the Douglas bag method at the start to 0.5% (0.021) lower at the end (p < 0.05). This study demonstrates that a computerized metabolic system with mixing chamber is an accurate system for measuring oxygen uptake. This applies to testing over a large range of ventilations and for stability both during shorter and longer test periods.
引用
收藏
页码:569 / 575
页数:7
相关论文
共 10 条
[1]   Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system [J].
Bassett, DR ;
Howley, ET ;
Thompson, DL ;
King, GA ;
Strath, SJ ;
McLaughlin, JE ;
Parr, BB .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (01) :218-224
[2]   ON-LINE COMPUTER ANALYSIS AND BREATH-BY-BREATH GRAPHICAL DISPLAY OF EXERCISE FUNCTION TESTS [J].
BEAVER, WL ;
WASSERMAN, K ;
WHIPP, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (01) :128-132
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Validity and reliability of three commercially available breath-by-breath respiratory systems [J].
Carter, J ;
Jeukendrup, AE .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 86 (05) :435-441
[5]   The most economical cadence increases with increasing workload [J].
Foss, O ;
Hallén, J .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 92 (4-5) :443-451
[6]   CPX/D underestimates VO2 in athletes compared with an automated Douglas bag system [J].
Gore, CJ ;
Clark, RJ ;
Shipp, NJ ;
van der Ploeg, GE ;
Withers, RT .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1341-1347
[7]   Oxidation of combined ingestion of glucose and fructose during exercise [J].
Jentjens, RLPG ;
Moseley, L ;
Waring, RH ;
Harding, LK ;
Jeukendrup, AE .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (04) :1277-1284
[8]   Delay time adjustments to minimize errors in breath-by-breath measurement of Vo(2) during exercise [J].
Proctor, DN ;
Beck, KC .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (06) :2495-2499
[9]   Validation of a computerized metabolic measurement system (Oxycon-Pro®) during low and high intensity exercise [J].
Rietjens, GJWM ;
Kuipers, H ;
Kester, ADM ;
Keizer, HA .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2001, 22 (04) :291-294
[10]  
SALMINEN R, 1982, MED PROG TECHNOL, V9, P27