Association between prevalent care process measures and facility-specific mortality rates

被引:22
作者
Lowrie, EG
Teng, M
Lacson, E
Lew, N
Lazarus, JM
Owen, WF
机构
[1] Fresenius Med Care NA Inc, Hlth Informat Serv, Lexington, MA 02173 USA
[2] Duke Univ, Med Ctr, Duke Inst Renal Outcomes Res & Hlth Policy, Durham, NC USA
关键词
HCFA Core Indicators; practice guidelines; quality of care; statistical evaluation; dialysis; hemodialysis;
D O I
10.1046/j.1523-1755.2001.00029.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background. Medical communities often develop practice guidelines recommending certain care processes intended to promote better clinical outcome among patients. Conformance with those guidelines by facilities is then monitored to evaluate care quality, presuming that the process is associated with and can be used reliably to predict clinical outcome. Outcome is often monitored as a facility-specific mortality rate (SMR) standardized to the mix of patients treated, also presuming that inferior outcome implies a suboptimal process. The U.S. Health Care Financing Administration monitors three practice guidelines, called Core Indicators, in dialysis facilities to assist management of its end-stage renal disease program: (1) patients' hematocrit values should exceed 30 vol%, (2) the urea reduction ratio (URR) during dialysis should equal or exceed 65%, and (3) patients' serum albumin concentrations should equal or exceed 3.5 g/dL. Methods. The associations of a facility-specific SMR were evaluated with the fractions of hemodialysis patients not conforming to (that is, at variance with) the Core Indicators during three successive years (1993 to 1995) in large numbers of facilities (394, 450, and 498) using one-variable and multivariable statistical models. Three related strategies were used. First, the association of the SMR with the fraction of patients not meeting the guideline was evaluated. Second, each facility was classified by whether its SMR exceeded the 80% confidence interval above 1.0 (worse than 1.0, Group 3), was less than the interval below 1.0 (better than 1.0, Group 1), or was within the interval (Group 2). The fraction of those patients who did not meet the Indicator guidelines was then evaluated in each group. Third, the ability of variance from Indicator guidelines to predict into which of the three SMR groups a facility would be categorized was evaluated. Results. SMR was directly correlated with variance from the Indicator guidelines, but the strengths of the associations were weak particularly for the hematocrit (R-2 = 2.2%, 5.6, and 2.2 for each of the 3 years) and URR Indicators (R-2 = 2.6, 0.6, 3.3). It was stronger for the albumin Indicator (R-2 = 11.6, 20.4, 21.8). The fractions of patients falling outside of the Indicator guidelines tended to be higher in the highest SMR group. The groups were not well separated, however, particularly for the hematocrit and URR Indicators, and there was substantial overlap between them. Finally, although the likelihood that a facility would be a member of the high or low SMR group was associated with fractional variance from Core Indicator guidelines, the strengths of association were weak, and the probability that a facility would be a member of the high or low group could not be easily distinguished from the probability that it would be a member of the middle group. Conclusions. While there were statistical associations between SMR and the fraction of patients in facilities who were at variance with these guidelines, they were weak and variances from the guidelines could not be used reliably to predict high or low SMR. Such findings do not imply that measures reflecting anemia, dialysis dose, or medical processes that influence serum albumin concentration are irrelevant to the quality of care. They do suggest, however, that more attention needs be paid to these and other associates and causes of mortality among dialysis patients when developing care process indicator guidelines.
引用
收藏
页码:1917 / 1929
页数:13
相关论文
共 34 条
[11]   Relationship between urea reduction ratio, demographic characteristics, and body weight for patients in the 1996 national ESRD core indicators project [J].
Frankenfield, DL ;
McClellan, WM ;
Helgerson, SD ;
Lowrie, EG ;
Rocco, MV ;
Owen, WF .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 33 (03) :584-591
[12]   Racia/ethnic analysis of selected intermediate outcomes for hemodialysis patients: Results from the 1997 ESRD Core Indicators Project [J].
Frankenfield, DL ;
Rocco, MV ;
Frederick, PR ;
Pugh, J ;
McClellan, WM ;
Owen, WF .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 34 (04) :721-730
[13]  
*HLTH CAR FIN ADM, 1994, COR IND PROJ IN RES
[14]  
*HLTH CAR FIN ADM, 1999, 1999 ANN REP ESRD CL
[15]  
*HLTH CAR FIN ADM, 1998, ANN REP ESRD COR IND
[16]   Body weight-for-height relationships predict mortality in maintenance hemodialysis patients [J].
Kopple, JD ;
Zhu, XF ;
Lew, NL ;
Lowrie, EG .
KIDNEY INTERNATIONAL, 1999, 56 (03) :1136-1148
[17]   Limitations of the facility-specific standardized mortality ratio for profiling health care quality in dialysis [J].
Lacson, E ;
Teng, M ;
Lazarus, JM ;
Lew, N ;
Lowrie, EG ;
Owen, WF .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 37 (02) :267-275
[18]  
Lowrie E G, 1998, Am J Kidney Dis, V32, pS16, DOI 10.1016/S0272-6386(98)70158-1
[19]   DEATH RISK PREDICTORS AMONG PERITONEAL-DIALYSIS AND HEMODIALYSIS-PATIENTS - A PRELIMINARY COMPARISON [J].
LOWRIE, EG ;
HUANG, WH ;
LEW, NL .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1995, 26 (01) :220-228
[20]   DEATH RISK IN HEMODIALYSIS-PATIENTS - THE PREDICTIVE VALUE OF COMMONLY MEASURED VARIABLES AND AN EVALUATION OF DEATH RATE DIFFERENCES BETWEEN FACILITIES [J].
LOWRIE, EG ;
LEW, NL .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1990, 15 (05) :458-482