Introduction to time-of-flight secondary ion mass spectrometry application in chromatographic analysis

被引:9
作者
Orinák, A
Arlinghaus, HF
Vering, G
Orináková, R
Hellweg, S
机构
[1] Safarik Univ, Inst Chem Sci, Dept Phys & Analyt Chem, Kosice 04154, Slovakia
[2] Univ Munster, Inst Phys, D-48149 Munster, Germany
关键词
thin layer chromatography; interfacing; TOF-SIMS; methyl red; terpinolen; giberrelic acid;
D O I
10.1016/j.chroma.2004.09.056
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
New on-line analytical system coupling thin layer chromatography (TLC) and high selective identification unit-time of flight secondary ion mass spectrometry (TOF-SIMS) is introduced in this article. Chromatographic mixture separation and analyte surface deposition followed with surface TOF-SIMS analysis on-line allows to identify the analytes at trace and ultratrace levels. The selected analytes with different detectability and identification possibility were analysed in this hyphenated unit (Methyl Red indicator, Terpinolen and Giberrelic acid). Here, the chromatographic thin layer plays a universal role: separation unit, analyte depositing surface and TOF-SIMS interface, finally. Two depositing substrates and TOF-SIMS compatible interfaces were tested in above-mentioned interfacing unit: modified aluminium backed chromatographic thin layer and monolithic silica thin layer. The sets of positive and negative ions TOF-SIMS spectra obtained from different SIMS modes of analysis were used for analyte identification purposes. SIMS enables analyte detection with high mass resolution at the concentration level that is not achieved by other methods. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 12 条
[1]  
BUSCHMANN N, 1996, NEW SURFACTANTS, V33, P1
[2]   Interfaces to connect thin-layer chromatography with electrospray ionization mass spectrometry [J].
Hsu, FL ;
Chen, CH ;
Yuan, CH ;
Shiea, J .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2493-2498
[3]  
MERSCHEL L, 1997, THESIS WILHELMS U MU
[4]   Modified chromatographic thin layer surface as an interface to couple thin layer chromatography with ToF-SIMS [J].
Orinak, A ;
Arlinghaus, HF ;
Vering, G ;
Orináková, R .
SURFACE AND INTERFACE ANALYSIS, 2004, 36 (08) :1122-1125
[5]   Reagents for detection of carboxylate anion ligands after chromatographic separation of zinc carboxylato complexes [J].
Orinák, A ;
Adámová, M ;
Halás, L ;
Tomcík, P ;
Justinová, M .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2003, 16 (04) :286-288
[6]   New interfaces for coupling TLC with TOF SIMS [J].
Orinák, A ;
Arlinghaus, HF ;
Vering, G ;
Justinová, M ;
Orináková, R ;
Turcániová, L ;
Halama, M .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2003, 16 (01) :23-27
[7]   TLC-TOF SIMS monitoring of zinc complex origin -: Carboxylate ligand movement [J].
Orinák, A ;
Crone, C ;
Benninghoven, A ;
Buschmann, N ;
Orinaková, R ;
Arlinghaus, HF ;
Justinová, M .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2002, 15 (04) :286-288
[8]  
ORINAK A, 2004, 11 S APPL CHROM IND
[9]  
ORINAK A, 2001, THESIS TU KOSICE
[10]   Thin-layer chromatography and electrospray mass spectrometry coupled using a surface sampling probe [J].
Van Berkel, GJ ;
Sanchez, AD ;
Quirke, JME .
ANALYTICAL CHEMISTRY, 2002, 74 (24) :6216-6223