New interfaces for coupling TLC with TOF SIMS

被引:9
作者
Orinák, A
Arlinghaus, HF
Vering, G
Justinová, M
Orináková, R
Turcániová, L
Halama, M
机构
[1] Safarik Univ, Inst Chem Sci, Dept Phys & Analyt Chem, Kosice 04001, Slovakia
[2] Univ Munster, Inst Phys, D-48149 Munster, Germany
[3] Slovak Acad Sci, Inst Geotech, Kosice 04145, Slovakia
关键词
TLC-TOF SIMS; interface; reversed-phase TLC; zinc complexes; coupling TLC and MS;
D O I
10.1556/JPC.16.2003.1.5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two interfaces have been tested for coupling thin-layer chromatography (TLC) with time-of-flight secondary-ion mass spectrometry (TOF SIMS). The first interface was formed by vacuum deposition of silver on to the chromatographic layer and on to a track formed by scraping the layer from the glass plate. The unmodified aluminum backing of a TLC plate (again formed by scraping adsorbent from the plate) was used as the second interface. TOF SIMS analysis of separated spot extracts on silver targets was performed for comparison of results. From TOF SIMS spectra it was found that although unmodified aluminum-backed plates result in a low background intensity the interface is not highly suitable because the analyte mass does not move suitably on to the interface. Transfer to the interface is irregular - the analyte spot becomes spread and does not occupy the same chromatographic position (R-F) on the interface as on the chromatographic layer. The positions of analytes tested on the silver-coated interface were regular, and three specific single ion intensities from the mass spectrum were obtained.
引用
收藏
页码:23 / 27
页数:5
相关论文
共 13 条
  • [1] Cserhati T, 1998, J AOAC INT, V81, P329
  • [2] APPARATUS FOR THE ISOLATION OF MICROGRAM AMOUNTS OF COMPOUNDS FROM THIN-LAYERS BY ELUTION AND DIRECT MILLIPORE FILTRATION
    DEKKER, D
    [J]. JOURNAL OF CHROMATOGRAPHY, 1979, 168 (02): : 508 - 511
  • [3] DEWASCH K, 1998, 5 INT S HYPH TECHN C
  • [4] MERSCHEL L, 1997, THESIS MUENSTER
  • [5] THIN-LAYER CHROMATOGRAPHY MASS-SPECTROMETRY - THE ADVANTAGES OF TANDEM MASS-SPECTROMETRY
    MONAGHAN, JJ
    MORDEN, WE
    JOHNSON, T
    WILSON, ID
    MARTIN, P
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (10) : 608 - 615
  • [6] DESIGN AND PERFORMANCE OF A REFLECTRON BASED TIME-OF-FLIGHT SECONDARY ION MASS-SPECTROMETER WITH ELECTRODYNAMIC PRIMARY ION MASS SEPARATION
    NIEHUIS, E
    HELLER, T
    FELD, H
    BENNINGHOVEN, A
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1987, 5 (04): : 1243 - 1246
  • [7] Mass spectrometric analysis of tetracycline antibiotics in foods
    Oka, H
    Ito, Y
    Ikai, Y
    Kagami, T
    Harada, K
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) : 309 - 319
  • [8] TLC-TOF SIMS monitoring of zinc complex origin -: Carboxylate ligand movement
    Orinák, A
    Crone, C
    Benninghoven, A
    Buschmann, N
    Orinaková, R
    Arlinghaus, HF
    Justinová, M
    [J]. JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2002, 15 (04) : 286 - 288
  • [9] Orinák A, 1998, J CHROMATOGR A, V825, P189
  • [10] ORINAK A, 1998, UNPUB