The use of polymeric solid phase extraction and HPLC analysis for the determination of ranitidine in routine plasma samples obtained from paediatric patients

被引:6
作者
Hare, LG
Millership, JS
Collier, PS
McElnay, JC
Carson, DJ
Shields, MS
机构
[1] Queens Univ Belfast, Sch Pharm, Ctr Med Biol, Belfast BT9 7BL, Antrim, North Ireland
[2] Queens Univ Belfast, Inst Clin Sci, Dept Child Hlth, Belfast BT12 6BJ, Antrim, North Ireland
关键词
D O I
10.1211/0022357011776559
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A sensitive HPLC method for the determination of ranitidine in small-volume (0.5 mL) paediatric plasma samples is described. Plasma samples were extracted using a simple, rapid solid phase extraction (SPE) technique developed using disposable copolymer packed SPE cartridges. Chromatographic separation was achieved by reverse-phase HPLC with isocratic elution using a mu Bondapak C-18 column and a phosphate buffer (10 mM, pH 3.75)-acetonitrile (87:13 v/v) mobile phase with UV detection at 313 nm. The HPLC system exhibited linearity in the range 8-800 ng mL(-1). Intraday % CV and % bias values were in the range 1.28-8.09% (% bias-4.33 to -0.87) and interday % CV and % bias values were in the range 0.73-15.28% (% bias-1.80 to +1.65). The limits of detection and quantitation obtained were 2 ng mL(-1) and 8 ng mL(-1), respectively, and ranitidine extraction recoveries from plasma ranged from 92.30 to 103.88%. in this study, the developed HPLC and SPE methodologies have been successfully applied to the determination of ranitidine concentrations in 68 paediatric plasma samples. The sampled population was drawn from patients already receiving the study drug therapeutically. Patients recruited had received ranitidine by two main routes-oral and intravenous. The plasma concentrations of ranitidine encountered in paediatric samples following oral or intravenous administration of a range of prescribed doses are presented graphically. These profiles are based on analysis of the first 68 plasma samples obtained from the first 35 patients recruited to the study receiving ranitidine by the oral or intravenous route.
引用
收藏
页码:1265 / 1272
页数:8
相关论文
共 20 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF RANITIDINE IN HUMAN PLASMA [J].
ALKHAMIS, KI ;
ELSAYED, YM ;
ALRASHOOD, KA ;
BAWAZIR, SA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (02) :277-286
[2]  
[Anonymous], 1998, Guidance for Industry Environmental Assessment of Human Drug and Biologics Applications, P1
[3]  
BOUTAGY J, 1984, J LIQ CHROMATOGR, V7, P1651, DOI 10.1080/01483918408074073
[4]   Rapid determination of ranitidine in human plasma by high-performance liquid chromatography [J].
Campanero, MA ;
Lopez-Ocariz, A ;
Garcia-Quetglas, E ;
Sadaba, B ;
de la Maza, A .
CHROMATOGRAPHIA, 1998, 47 (7-8) :391-395
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR THE DETERMINATION OF RANITIDINE IN PLASMA [J].
CAREY, PF ;
MARTIN, LE .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1979, 2 (09) :1291-1303
[6]   Survey of unlicensed and off label drug use in paediatric wards in European countries [J].
Conroy, S ;
Choonara, I ;
Impicciatore, P ;
Mohn, A ;
Arnell, H ;
Rane, AR ;
Knoeppel, C ;
Seyberth, H ;
Pandolfini, C ;
Raffaelli, MP ;
Rocchi, F ;
Bonati, M ;
't Jong, G ;
de Hoog, M ;
van den Anker, J .
BRITISH MEDICAL JOURNAL, 2000, 320 (7227) :79-82
[7]  
*EURACHEM, 1998, FITN PURP AN METH LA, P1
[8]   Solid-phase extraction and determination of ranitidine in human plasma by a high-performance liquid chromatographic method utilizing midbore chromatography [J].
Farthing, D ;
Brouwer, KLR ;
Fakhry, I ;
Sica, D .
JOURNAL OF CHROMATOGRAPHY B, 1997, 688 (02) :350-353
[9]  
GARG DC, 1981, CLIN PHARMACOL THER, V29, P247
[10]   AUTOMATED SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF RANITIDINE FROM URINE, PLASMA AND PERITONEAL DIALYSATE [J].
KARNES, HT ;
OPONGMENSAH, K ;
FARTHING, D ;
BEIGHTOL, LA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 422 :165-173