Prospective sonographic study of 3093 breast tumors

被引:43
作者
Chao, TC
Lo, YF
Chen, SC
Chen, MF
机构
[1] Chang Gung Mem Hosp, Dept Surg, Taipei 10591, Taiwan
[2] Chang Gung Univ, Coll Med, Dept Surg, Div Gen Surg, Taipei, Taiwan
关键词
echogenicity; fibroadenoma; invasive ductal carcinoma; microcalcification;
D O I
10.7863/jum.1999.18.5.363
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
To evaluate the predictive ability of sonographic tumor characteristics to differentiate benign from malignant tumors, we examined 3093 breast tumors (2360 benign and 733 malignant tumors) with ultrasonography. The ratio of the longest dimension to the anteroposterior diameter of benign tumors was significantly larger than that of malignant tumors (1.88 +/- 0.1 versus 1.69 +/- 0.02, P < 0.0001). Shape, margins, echogenicity, internal echo pattern, retro-tumor acoustic shadowing, compressibility, and microcalcification were significant factors in the logistic regression model. The sensitivity, specificity,positive predictive value, negative predictive value, and accuracy of breast sonography for malignancy were 86.1, 66.1, 44.1, 93.9, and 70.8%, respectively. Biopsy of the tumor for pathologic diagnosis is recommended if sonographic features are suggestive of malignancy.
引用
收藏
页码:363 / 370
页数:8
相关论文
共 35 条
[11]   ULTRASONIC-ATTENUATION IN FIBROADENOMA OF THE BREAST [J].
GUYER, PB ;
DEWBURY, KC ;
RUBIN, CM ;
BUTCHER, C ;
ROYLE, GT ;
THEAKER, J .
CLINICAL RADIOLOGY, 1992, 45 (03) :175-178
[12]  
GUYER PB, 1986, CLIN RADIOL, V37, P458
[13]   Sonography of the breast: Controversies and opinions [J].
Hall, FM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (06) :1635-1636
[14]   ULTRASOUND IN THE EVALUATION OF SOLID BREAST MASSES [J].
HARPER, AP ;
KELLYFRY, E ;
NOE, JS ;
BIES, JR ;
JACKSON, VP .
RADIOLOGY, 1983, 146 (03) :731-736
[15]   REAL-TIME SONOGRAPHY OF PALPABLE BREAST MASSES [J].
HAYASHI, N ;
TAMAKI, N ;
YONEKURA, Y ;
SENDA, M ;
YAMAMOTO, K ;
TORIZUKA, K ;
HORI, T ;
INAMOTO, T ;
OHGAKI, K ;
KODAMA, H .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (691) :611-615
[16]  
JACKSON VP, 1989, SEMIN ULTRASOUND CT, V10, P119
[17]   THE ROLE OF US IN BREAST IMAGING [J].
JACKSON, VP .
RADIOLOGY, 1990, 177 (02) :305-311
[18]   IMAGING OF THE RADIOGRAPHICALLY DENSE BREAST [J].
JACKSON, VP ;
HENDRICK, RE ;
FEIG, SA ;
KOPANS, DB .
RADIOLOGY, 1993, 188 (02) :297-301
[19]   AUTOMATED BREAST SONOGRAPHY USING A 7.5-MHZ PVDF TRANSDUCER - PRELIMINARY CLINICAL-EVALUATION - WORK IN PROGRESS [J].
JACKSON, VP ;
KELLYFRY, E ;
ROTHSCHILD, PA ;
HOLDEN, RW ;
CLARK, SA .
RADIOLOGY, 1986, 159 (03) :679-684