The right ventricular outflow tract: A comparative study of septal, anterior wall, and free wall pacing

被引:37
作者
Hillock, Richard J. [1 ]
Stevenson, Irene H. [1 ]
Mond, Harry G. [1 ]
机构
[1] Royal Melbourne Hosp, Dept Cardiol, Private Med Ctr, Melbourne, Vic 3050, Australia
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2007年 / 30卷 / 08期
关键词
selective-site pacing; right ventricular outflow tract pacing;
D O I
10.1111/j.1540-8159.2007.00790.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: There is marked heterogeneity in right ventricular outflow tract (RVOT) pacemaker lead placement using conventional leads. As a result, we have sought to identify a reproducible way of placing a ventricular lead onto the RVOT septum. Methods and Results: A major determinant is the shape of the stylet used to deliver the active-fixation lead. We compared stylet shapes and configurations in patients who initially had a ventricular lead placed onto the anterior or free wall of the RVOT and then had the lead repositioned onto the septum. All leads were loaded with a stylet fashioned with a distal primary curve to facilitate delivery of the lead to the pulmonary artery, then using a pullback technique the lead was retracted to the RVOT All lead placements were confirmed by fluoroscopy and electrocardiography. Anterior or free wall placement was achieved by the stylet having either the standard curve or an added distal anterior angulation. In contrast, septal lead positioning was uniformly achieved by a distal posterior angulation of the curved stylet. This difference in tip shape was highly predictive for septal placement (P < 0.001). With septal pacing, a narrower QRS duration was noted, compared to anterior or free wall pacing (136 vs 155 ms, P < 0.001). All pacing parameters were within acceptable limits. Conclusion: Using appropriately shaped stylets, pacing leads can now be placed into specific positions within the RVOT and in particular sepal pacing can be reliably and reproducibly achieved. This is an important step in the standardization of lead placement in the RVOT.
引用
收藏
页码:942 / 947
页数:6
相关论文
共 18 条
  • [1] Ventricular-based pacing: One site fits all?
    Brady, PA
    Hammill, SC
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (11) : 1187 - 1188
  • [2] SEPTAL SHORT ATRIOVENTRICULAR DELAY PACING - ADDITIONAL HEMODYNAMIC IMPROVEMENTS IN HEART-FAILURE
    COWELL, R
    MORRISTHURGOOD, J
    ILSLEY, C
    PAUL, V
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1980 - 1983
  • [3] TOTAL EXCITATION OF ISOLATED HUMAN HEART
    DURRER, D
    VANDAM, RT
    FREUD, GE
    JANSE, MJ
    MEIJLER, FL
    ARZBAECHER, RC
    [J]. CIRCULATION, 1970, 41 (06) : 899 - +
  • [4] Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: Implant safety and electrical performance
    Gammage, Michael D.
    Lieberman, Randy A.
    Yee, Raymond
    Manolis, Antonis S.
    Compton, Steven J.
    Khazen, Cesar
    Schaaf, Katie
    Oleson, Kimberly A.
    Crossley, George H.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (08): : 858 - 865
  • [5] Comparative left ventricular function following atrial, septal, and apical single chamber heart pacing in the young
    Karpawich, PP
    Mital, S
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (08): : 1983 - 1988
  • [6] Rapid decline in acute stimulation thresholds with steroid-eluting active-fixation pacing leads
    Kistler, PM
    Kalman, JM
    Fynn, SP
    Singarayar, S
    Roberts-Thomson, KC
    Lindsay, CB
    Khong, U
    Sparks, PB
    Strathmore, N
    Mond, HG
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (09): : 903 - 909
  • [7] Selective site pacing: Defining and reaching the selected site
    Lieberman, R
    Grenz, D
    Mond, HG
    Gammage, MD
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (06): : 883 - 886
  • [8] LUNDEEN T, 1997, PACING CLIN ELECTROP, V20, P1210
  • [9] Right ventricular outflow tract pacing: Radiographic and Electrocardiographic correlates of lead position
    McGavigan, Andrew D.
    Roberts-Thomson, Kurt C.
    Hillock, Richard J.
    Stevenson, Irene H.
    Mond, Harry G.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (10): : 1063 - 1068
  • [10] The right ventricular outflow tract: The road to septal pacing
    Mond, Harry G.
    Hillock, Richard J.
    Stevenson, Irene H.
    Mcgavigan, Andrew D.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (04): : 482 - 491