Relationship between compressive properties of human os calcis cancellous bone and microarchitecture assessed from 2D and 3D synchrotron microtomography

被引:31
作者
Follet, H
Bruyère-Garnier, K
Peyrin, F
Roux, JP
Arlot, ME
Burt-Pichat, B
Rumelhart, C
Meunier, PJ
机构
[1] INSA Lyon, CNRS, UMR 5515, CREATIS, Lyon, France
[2] ESRF, F-38043 Grenoble, France
[3] INSERM, U403, Lab Histodynam Osseuse, Fac Laennec, F-69008 Lyon, France
[4] INSA Lyon, CNRS, UMR 5514, LaMCoS, Lyon, France
关键词
bone morphometry; computed tomography; cancellous bone; mechanical testing; calcaneus;
D O I
10.1016/j.bone.2004.10.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to determine the contribution of 2D and 3D microarchitectural characteristics in the assessment of the mechanical strength of os calcis cancellous bone. A sample of cancellous bone was removed in a medio-lateral direction from the posterior body of calcaneus, taken at autopsy in 17 subjects aged 61-91 years. The sample was first used for the assessment of morphological parameters from 2D morphometry and 3D synchrotron microtomography (mu CT) (spatial resolution 10 mu m). The 2D morphometry was obtained from three slices extracted from the 3D mu CT images. Very good concordance was shown between 3D mu CT slices and the corresponding physical histologic slices. In 2D, the standard histomorphometric parameters, fractal dimension, mean intercept length, and connectivity were computed. In 3D, histomorphometric parameters were computed using both the 31) mean intercept length method and model-independent techniques. The 3D fractal dimension and the 3D connectivity, assessed by Euler density, were also evaluated. The cubic samples were subjected to elastic compressive tests in three orthogonal directions (X, Y, Z) close to the main natural trabecular network directions. A test was performed until collapse of trabecular network in the main direction (Z). The mechanical properties were significantly correlated to most morphological parameters resulting from 2D and 3D analysis. In 2D, the correlation between the mechanical strength and bone volume/tissue volume was not significantly improved by adding structural parameters or connectivity parameter (nodes number/tissue volume). In 3D, one architectural parameter (the trabecular thickness, Tb.Th) permitted to improve the estimation of the compressive strength from the bone volume/tissue volume alone. However, this improvement was minor since the correlation with the BV/TV alone was high (r 0.96). In conclusion, which is in agreement with the statistic's rules, we found, in this study, that the determination of the os calcis bone compressive strength using the 3D bone volume fraction cannot be improved by adding 3D architectural parameters. (c) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:340 / 351
页数:12
相关论文
共 68 条
[1]  
AARON JE, 1987, CLIN ORTHOP RELAT R, P260
[2]   A CONTINUOUS WAVE TECHNIQUE FOR THE MEASUREMENT OF THE ELASTIC PROPERTIES OF CORTICAL BONE [J].
ASHMAN, RB ;
COWIN, SC ;
VANBUSKIRK, WC ;
RICE, JC .
JOURNAL OF BIOMECHANICS, 1984, 17 (05) :349-361
[3]   Evaluation of changes in trabecular bone architecture and mechanical properties of minipig vertebrae by three-dimensional magnetic resonance microimaging and finite element modeling [J].
Borah, B ;
Dufresne, TE ;
Cockman, MD ;
Gross, GJ ;
Sod, EW ;
Myers, WR ;
Combs, KS ;
Higgins, RE ;
Pierce, SA ;
Stevens, ML .
JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (09) :1786-1797
[4]   High-resolution computed tomography for architectural characterization of human lumbar cancellous bone: Relationships with histomorphometry and biomechanics [J].
Cendre, E ;
Mitton, D ;
Roux, JP ;
Arlot, ME ;
Duboeuf, F ;
Burt-Pichat, B ;
Rumelhart, C ;
Peix, G ;
Meunier, PJ .
OSTEOPOROSIS INTERNATIONAL, 1999, 10 (05) :353-360
[5]  
Chappard D., 1999, Morphologie, V83, P17
[6]   Accuracy of cancellous bone volume fraction measured by micro-CT scanning [J].
Ding, M ;
Odgaard, A ;
Hvid, I .
JOURNAL OF BIOMECHANICS, 1999, 32 (03) :323-326
[7]   HIGH SPATIAL-RESOLUTION IMAGING OF BONE-MINERAL USING COMPUTED MICROTOMOGRAPHY - COMPARISON WITH MICRORADIOGRAPHY AND UNDECALCIFIED HISTOLOGIC SECTIONS [J].
ENGELKE, K ;
GRAEFF, W ;
MEISS, L ;
HAHN, M ;
DELLING, G .
INVESTIGATIVE RADIOLOGY, 1993, 28 (04) :341-349
[8]   Assessing the accuracy of high-resolution X-ray computed tomography of primate trabecular bone by comparisons with histological sections [J].
Fajardo, RJ ;
Ryan, TM ;
Kappelman, J .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2002, 118 (01) :1-10
[9]   Three-dimensional analysis of nonhuman primate trabecular architecture using micro-computed tomography [J].
Fajardo, RJ ;
Müller, R .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2001, 115 (04) :327-336
[10]  
Fazzalari NL, 1996, J PATHOL, V178, P100, DOI 10.1002/(SICI)1096-9896(199601)178:1<100::AID-PATH429>3.0.CO