Weaning prediction - Esophageal pressure monitoring complements readiness testing

被引:92
作者
Jubran, A
Grant, BJB
Laghi, F
Parthasarathy, S
Tobin, MJ
机构
[1] Vet Affairs Edward Hines Jr Hosp, Div Pulm & Crit Care Med, Hines, IL 60141 USA
[2] Loyola Univ Chicago, Stritch Sch Med, Hines, IL USA
[3] SUNY Buffalo, Vet Affairs Hlth Care Syst Western New York, Buffalo, NY 14260 USA
关键词
esophageal pressure; monitoring; weaning;
D O I
10.1164/rccm.200503-356OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Several variables are recommended for identifying if a patient is ready for a trial of weaning from mechanical ventilation, but there is no agreement as to whether monitoring any variable during the trial enhances patient management. To determine whether repeated measurements of esophageal pressure throughout a trial are more reliable than measurements of esophageal pressure or frequency-to-V-T ratio during the first minute of the trial, we studied 60 patients. A trend index that quantified esophageal pressure swings over time was more reliable than the first-minute measurements: sensitivity, 0.91, and specificity, 0.89. Area under receiver operating characteristic curve for trend index (0.94) was greater than for first-minute measurement of esophageal pressure (0.44, p < 0.05) and tended to be greater than that for frequency-to-V-T ratio (0.78, p = 0.13). The likelihood ratio was highest for the trend index (8.2, p < 0.05). The advantage of the trend index may be related to the progressive increase in esophageal pressure throughout a failed weaning trial, whereas breathing pattern changed little after 2 minutes of spontaneous breathing. In conclusion, continuous monitoring of esophageal pressure swings during a spontaneous breathing trial provides additional guidance in patient management over tests used for deciding when to initiate weaning.
引用
收藏
页码:1252 / 1259
页数:8
相关论文
共 36 条
[31]   Clinical characteristics, respiratory functional parameters, and outcome of a two-hour T-piece trial in patients weaning from mechanical ventilation [J].
Vallverdú, I ;
Calaf, N ;
Subirana, M ;
Net, A ;
Benito, S ;
Mancebo, J .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (06) :1855-1862
[32]   The tension-time index and the frequency/tidal volume ratio are the major pathophysiologic determinants of weaning failure and success [J].
Vassilakopoulos, T ;
Zakynthinos, S ;
Roussos, C .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (02) :378-385
[33]   A PROSPECTIVE-STUDY OF INDEXES PREDICTING THE OUTCOME OF TRIALS OF WEANING FROM MECHANICAL VENTILATION [J].
YANG, KL ;
TOBIN, MJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (21) :1445-1450
[34]   LOAD RESPONSES, DYSPNEA, AND RESPIRATORY-FAILURE [J].
YOUNES, M .
CHEST, 1990, 97 (03) :S59-S68
[35]  
YOUNES M, 1995, REGULATION BREATHING, P867
[36]  
Zin WA., 1998, PRINCIPLES PRACTICE, P545