Multicommutation cold vapour atomic fluorescence determination of Hg in water

被引:25
作者
Reis, BF [1 ]
Ródenas-Torralba, E [1 ]
Sancenón-Buleo, J [1 ]
Morales-Rubio, A [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Valencia, Spain
关键词
multicommutation; Hg determination; atomic fluorescence spectrometry; cold vapour; water analysis;
D O I
10.1016/S0039-9140(03)00127-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multicommutation-based method has been developed for the on-line direct atomic fluorescence spectrometric (AFS) determination of Hg in waters without any previous sample treatment. The performance of the proposed procedure has been compared with that of a conventional AFS system based on continuous mode measurements. In short, the use of multicommutation, together with a reduction of the size of the liquid-gas phase separator, provides an increase of the laboratory productivity by improving the sample throughput by a factor of 3.6 and strongly reduces the sample consumed by a factor of 6 and reagent consumed by a factor of 8.4. The waste generation is reduced by a factor of 2.4 and the Ar consumed by a factor of 6, thus the developed method is an environmentally and economically sustainable alternative to the methodology based on continuous measurements, without any reduction of the analytical sensitivity and with an enhancement of the repeatability of measurements. Only the limit of detection was poorer for the methodology developed (1.3 ng l(-1)) than that found by the classical continuous mode (0.3 ng l(-1)). The aforementioned methodologies were applied to the determination of Hg in water samples having obtained comparable values by both procedures and with those found by an external laboratory. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:809 / 819
页数:11
相关论文
共 26 条
[1]   SANDWICH TECHNIQUES IN FLOW-INJECTION ANALYSIS .3. SIMULTANEOUS DETERMINATION OF CR(VI) IN 2 CONCENTRATION RANGES [J].
ALONSOCHAMARRO, J ;
BARTROLI, J ;
BARBER, R .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :219-223
[2]   MERGING ZONES IN FLOW INJECTION ANALYSIS .1. DOUBLE PROPORTIONAL INJECTOR AND REAGENT CONSUMPTION [J].
BERGAMIN, H ;
ZAGATTO, EAG ;
KRUG, FJ ;
REIS, BF .
ANALYTICA CHIMICA ACTA, 1978, 101 (01) :17-23
[3]   Automatic stepwise potentiometric titration in a monosegmented flow system [J].
Borges, EP ;
Martelli, PB ;
Reis, BF .
MIKROCHIMICA ACTA, 2000, 135 (3-4) :179-184
[4]   Cold vapour atomic fluorescence studies on the behaviour of mercury(II) and mercury(II)-thiol complexes. An alternative route for characterization of -SH binding groups [J].
Bramanti, E ;
D'Ulivo, A ;
Lampugnani, L ;
Raspi, G ;
Zamboni, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (02) :179-185
[5]   Selective determination of thiolic proteins by hydrophobic interaction chromatography coupled with on-line cold vapour atomic fluorescence spectrometry [J].
Bramanti, E ;
Lucchesini, S ;
D'Ulivo, A ;
Lampugnani, L ;
Zamboni, R ;
Spinetti, MC ;
Raspi, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (02) :166-171
[6]   Trace determination of mercury: A review [J].
Clevenger, WL ;
Smith, BW ;
Winefordner, JD .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1997, 27 (01) :1-26
[7]   TOWARDS ENVIRONMENTALLY CONSCIENTIOUS ANALYTICAL-CHEMISTRY THROUGH MINIATURIZATION, CONTAINMENT AND REAGENT REPLACEMENT [J].
DELAGUARDIA, M ;
RUZICKA, J .
ANALYST, 1995, 120 (02) :N17-N17
[8]   Storage of natural water samples for total and reactive mercury analysis in PET bottles [J].
Fadini, PS ;
Jardim, WF .
ANALYST, 2000, 125 (03) :549-551
[9]  
Jian Wei, 1992, Talanta, V39, P1537
[10]   Photochemical-fluorimetric determination of folic acid in a multicommutated flow system [J].
Lapa, RAS ;
Lima, JLFC ;
Reis, BF ;
Santos, JLM ;
Zagatto, EAG .
ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) :223-228