Echocardiographic considerations during deployment of the Helex Septal Occluder for closure of atrial septal defects

被引:8
作者
Lopez, L
Ventura, R
Welch, EM
Nykanen, DG
Zahn, EM
机构
[1] Miami Childrens Hosp, Div Pediat Cardiol, Miami, FL 33155 USA
[2] Miami Childrens Hosp, Heart Stn, Miami, FL 33155 USA
关键词
oval fossa defect; interventional catheterization; transesophageal echocardiography; three-dimensional reconstruction; intracardiac echocardiography;
D O I
10.1017/S1047951103000556
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The Helex Septal Occluder is a new device used to close atrial septal defects via interventional catheterization. In order to study the role of echocardiography during its use, and to describe the morphologic variants of defects suitable for closure with this occluder, we evaluated all patients undergoing intended closure of an atrial septal defect with the Helex occluder. A combination of transthoracic, transesophageal, three-dimensional, and intracardiac echocardiography were used before, during, and after the procedure to characterize anatomy, assess candidacy for closure, guide the device during its deployment, and evaluate results. Among the 60 candidates included in the study, 11 were excluded because of transesophageal echocardiographic and/or catheterization data obtained in the laboratory. Attempts at closure were successful in 46 patients, and unsuccessful in 3. We successfully treated four types of defects. These were defects positioned centrally within the oval fossa with appreciable rims along the entire circumference of the defect, defects with deficient or absent segments of the rim, defects with aneurysm of the primary atrial septum, and defects with multiple fenestrations. Follow-up transthoracic echocardiograms taken at a median of 7 months demonstrated no residual defects in 21, trivial residual defects in 17, and small residual defects in 8 patients. In 20 patients, three-dimensional reconstructions were used to characterize the morphology of the defect and the position of the device. Because transesophageal echocardiography was often limited by acoustic interference from the device, intracardiac echocardiography was utilized in 3 cases to overcome this limitation.
引用
收藏
页码:290 / 298
页数:9
相关论文
共 20 条
[1]
ECHOCARDIOGRAPHIC FOLLOW-UP OF ATRIAL SEPTAL-DEFECT AFTER CATHETER CLOSURE BY DOUBLE-UMBRELLA DEVICE [J].
BOUTIN, C ;
MUSEWE, NN ;
SMALLHORN, JF ;
DYCK, JD ;
KOBAYASHI, T ;
BENSON, LN .
CIRCULATION, 1993, 88 (02) :621-627
[2]
Transcatheter closure of multiple atrial septal defects - Initial results and value of two- and three-dimensional transoesophageal echocardiography [J].
Cao, QL ;
Radtke, W ;
Berger, F ;
Zhu, W ;
Hijazi, ZM .
EUROPEAN HEART JOURNAL, 2000, 21 (11) :941-947
[3]
CHAN KC, 1993, BRIT HEART J, V69, P52
[4]
Echocardiologists' role in the deployment of the Amplatzer Atrial Septal Occluder device in adults [J].
Cooke, JC ;
Gelman, JS ;
Harper, RW .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (06) :588-594
[5]
FERREIRA SMAG, 1992, BRIT HEART J, V67, P316
[6]
Transcatheter closure of atrial septal defects within the oval fossa: medium-term results in children using the 'ASDOS'-technique [J].
Hausdorf, G ;
Schneider, M ;
Fink, C ;
Neudorf, U ;
Fischer, G ;
Tynan, M ;
Friedli, B .
CARDIOLOGY IN THE YOUNG, 1998, 8 (04) :462-471
[7]
Hijazi ZM, 2001, CATHETER CARDIO INTE, V52, P194, DOI 10.1002/1522-726X(200102)52:2<194::AID-CCD1046>3.0.CO
[8]
2-4
[9]
SECUNDUM ATRIAL SEPTAL-DEFECT - NONOPERATIVE CLOSURE DURING CARDIAC-CATHETERIZATION [J].
KING, TD ;
THOMPSON, SL ;
STEINER, C ;
MILLS, NL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1976, 235 (23) :2506-2509
[10]
Latson, 2000, Curr Interv Cardiol Rep, V2, P268