Vascular virtual endoluminal visualization of invasive colorectal cancer on MDCT colonography

被引:3
作者
Iinuma, G
Moriyama, N
Satake, M
Miyakawa, K
Tateishi, U
Uchiyama, N
Akasu, T
Fujii, T
Kobayashi, T
机构
[1] Natl Canc Ctr, Canc Screening Div, Res Ctr Canc Prevent & Screening, Chuo Ku, Tokyo 1040045, Japan
[2] Natl Canc Ctr, Colorectal Surg Div, Chuo Ku, Tokyo, Japan
[3] Natl Canc Ctr, Diagnost Radiol Div, Chuo Ku, Tokyo, Japan
[4] Natl Canc Ctr, Endoscopy Div, Chuo Ku, Tokyo, Japan
关键词
D O I
10.2214/ajr.184.4.01841194
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to assess the utility of vascular views for visualization of invasive colorectal cancers on contrast-enhanced MDCT colonography. CONCLUSION. By means of Hounsfield-transparency settings, we obtained virtual endoluminal images that show vascular structures and delineate invasive cancers of the colorectal wall, and we call these images "vascular views." Using this technique for contrast-enhanced MDCT colonography, we found that the increase in flow and pooling of blood related to angiogenesis of cancerous lesions is easy to identify and that this finding is useful in the detection of invasive colorectal cancers.
引用
收藏
页码:1194 / 1198
页数:5
相关论文
共 12 条
[1]   Technical report: Spiral CT pneumocolon for suspected colonic neoplasms [J].
Amin, Z ;
Boulos, PB ;
Lees, WR .
CLINICAL RADIOLOGY, 1996, 51 (01) :56-61
[2]   Multidetector-array CT: Once again, technology creates new opportunities [J].
Berland, LL ;
Smith, JK .
RADIOLOGY, 1998, 209 (02) :327-329
[3]   Detection of colorectal polyps with CT colography: Initial assessment of sensitivity and specificity [J].
Hara, AK ;
Johnson, CD ;
Reed, JE ;
Ahlquist, DA ;
Nelson, H ;
MacCarty, RL ;
Harmsen, WS ;
Ilstrup, DM .
RADIOLOGY, 1997, 205 (01) :59-65
[4]   Helical CT pneumocolon to assess colonic tumors: Radiologic-Pathologic correlation [J].
Harvey, CJ ;
Amin, Z ;
Hare, CMB ;
Gillams, AR ;
Novelli, MR ;
Boulos, PB ;
Lees, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (06) :1439-1443
[5]   Lung: Feasibility of a method for changing tube current during low-dose helical CT [J].
Itoh, S ;
Ikeda, M ;
Mori, Y ;
Suzuki, K ;
Sawaki, A ;
Iwano, S ;
Satake, H ;
Arahata, S ;
Isomura, T ;
Ozaki, M ;
Ishigaki, T .
RADIOLOGY, 2002, 224 (03) :905-912
[6]   CT colonography: The next colon screening examination? [J].
Johnson, CD ;
Dachman, AH .
RADIOLOGY, 2000, 216 (02) :331-341
[7]   Performance evaluation of a multi-slice CT system [J].
McCollough, CH ;
Zink, FE .
MEDICAL PHYSICS, 1999, 26 (11) :2223-2230
[8]   Visualization of colorectal polyps with spiral CT colography: Evaluation of processing parameters with perspective volume rendering [J].
McFarland, EG ;
Brink, JA ;
Loh, J ;
Wang, G ;
Argiro, V ;
Balfe, DM ;
Heiken, JP ;
Vannier, MW .
RADIOLOGY, 1997, 205 (03) :701-707
[9]   A prospective single centre study comparing computed tomography pneumocolon against colonoscopy in the detection of colorectal neoplasms [J].
Miao, YM ;
Amin, Z ;
Healy, J ;
Burn, P ;
Murugan, N ;
Westaby, D ;
Allen-Mersh, TG .
GUT, 2000, 47 (06) :832-837
[10]   DETECTABILITY OF SPHERICAL OBJECTS BY COMPUTED-TOMOGRAPHY [J].
PLEWES, DB ;
DEAN, PB .
RADIOLOGY, 1979, 133 (03) :785-786