Lung: Feasibility of a method for changing tube current during low-dose helical CT

被引:12
作者
Itoh, S
Ikeda, M
Mori, Y
Suzuki, K
Sawaki, A
Iwano, S
Satake, H
Arahata, S
Isomura, T
Ozaki, M
Ishigaki, T
机构
[1] Nagoya Univ, Sch Med, Dept Tech Radiol, Showa Ku, Nagoya, Aichi 4668560, Japan
[2] Nagoya Univ, Sch Med, Dept Med Informat & Med Records, Showa Ku, Nagoya, Aichi 4668560, Japan
[3] Nagoya Univ, Sch Med, Dept Radiol, Showa Ku, Nagoya, Aichi 4668560, Japan
[4] Komaki City Hosp, Dept Radiol, Komaki, Japan
[5] Hokushin Gen Hosp, Dept Radiol, Nakano, Japan
关键词
cancer screening; computed tomography (CT); helical; image quality; lung neoplasms; CT; diagnosis;
D O I
10.1148/radiol.2243010874
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method for changing the tube current during helical scanning was applied to low-dose computed tomography (CT) in the lung. The changing method resulted in significant equalization of image noise in various lung sections compared with that at scanning with constant tube current. Detectability of nodules was equivalent between 60 mA and the changing method, whereas degradation occurred at 20 mA. This method seems feasible for the low-dose CT of lung cancer screening. (C) RSNA, 2002.
引用
收藏
页码:905 / 912
页数:8
相关论文
共 27 条
[1]  
AOYAMA T, 1999, KEK P, V99, P1
[2]  
DAVIS SD, 1991, RADIOLOGY, V180, P1
[3]   Pulmonary nodules: Experimental and clinical studies at low-dose CT [J].
Diederich, S ;
Lenzen, H ;
Windmann, R ;
Puskas, Z ;
Yelbuz, TM ;
Henneken, S ;
Klaiber, T ;
Eameri, M ;
Roos, N ;
Peters, PE .
RADIOLOGY, 1999, 213 (01) :289-298
[4]   Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[5]   THE EFFECT OF MAS VARIATION UPON COMPUTED-TOMOGRAPHY IMAGE QUALITY AS EVALUATED BY INVIVO AND INVITRO STUDIES [J].
HAAGA, JR ;
MIRALDI, F ;
MACINTYRE, W ;
LIPUMA, JP ;
BRYAN, PJ ;
WIESEN, E .
RADIOLOGY, 1981, 138 (02) :449-454
[6]  
HENRY R, 1998, RADIOLOGY, V209, P243
[7]  
HOCHBER Y, 1987, MULTIPLE COMP PROCED
[8]  
Ikeda M, 2001, METHOD INFORM MED, V40, P259
[9]   Lung cancer screening: Minimum tube current required for helical CT [J].
Itoh, S ;
Ikeda, M ;
Arahata, S ;
Kodaira, T ;
Isomura, T ;
Kato, T ;
Yamakawa, K ;
Maruyama, K ;
Ishigaki, T .
RADIOLOGY, 2000, 215 (01) :175-183
[10]  
Itoh S, 1998, Radiat Med, V16, P75